Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 256

The DOI matches its Crossref record.

Development and application of a two-site enzyme immunoassay for the determination of 'total' activin-A concentrations in serum and follicular fluid

Knight, P G, Muttukrishna, S, Groome, N P·1996·Journal of Endocrinology

Abstract

The performance of existing immunoassays and bioassays for activins is compromised by the presence of activin-binding proteins such as follistatin and α 2 macroglobulin (α 2 M) in biological fluids. To overcome this problem we have developed a novel two-site enzyme immunoassay procedure for activin-A which incorporates an analyte denaturation and oxidation step. The optimized assay is sensitive (detection limit ∼10 pg/well), precise (mean within- and between-plate coefficients of variation 4·9 and 9·1% respectively) and accurate (activin-A recovery values of 102 ± 3 and 96 ± 5% for bovine follicular fluid (FF) and human serum respectively). In specificity tests, high concentrations of follistatin (500 ng/ml) and α 2 M (100 μg/ml) did not interfere with the response signal to activin-A. In addition, no significant cross-reactivity was observed with a range of related molecules including inhibin-A, inhibin-B, activin-B (all <0·5%), bovine pro-αC and follistatin (both <0·1%). Response curves parallel to the activin-A standard curve were obtained for a variety of test samples including bovine, human, ovine and porcine FF, human sera and conditioned medium from cultured bovine and human granulosa cells. Fractionation of bovine FF by SDS-PAGE confirmed assay specificity since only one peak of activin-A immunoreactivity was detected (Mr ∼25 k) in eluted gel slices. However, gel-permeation chromatography showed that under physiological conditions all of the detectable activin-A in bovine FF eluted with apparent Mr values of >700 and 60–200 k reflecting its association with binding protein(s). Analysis of bovine FF samples (n=76) from morphologically dominant follicles during the luteal phase showed that activin-A levels were positively correlated with inhibin-A (r=+0·54; P<0·001) and total β subunit immunoreactivity (r=+0·32; P<0·005) but not with total α subunit immunoreactivity (r= −0·09). Classification of these follicles according to oestrogenic status showed that activin-A, inhibin-A and total β subunit levels were highest in oestrogen-inactive follicles (P<0·01) whereas total α subunit levels were lowest in these follicles (P<0·001). Activin-A levels were measurable in all human serum samples analysed, ranging from 128 pg/ml during the normal menstrual cycle, 210 pg/ml in women undergoing ovarian hyperstimulation and ∼ 500 pg/ml in postmenopausal women to over 4000 pg/ml during pregnancy. In conclusion, the present assay provides a reliable method for quantitating total (i.e. bound+free) activin-A concentrations in a variety of biological samples and should prove useful for further in vivo and in vitro studies in a range of species including man. Journal of Endocrinology (1996) 148, 267–279

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1677/joe.0.1480267

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 256

Metadata

Authors
Knight, P. G., Muttukrishna, S., & Groome, N. P.
Venue
Journal of Endocrinology
Published
1996-02
Volume
148
Issue
2
Pages
267-279
ISSN
  • 0022-0795 (ISSN-L)
  • 1479-6805
OpenAlex
W2053207886
Cited by
256
References
0
FWCI
7.05
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Development and application of a two-site enzyme immunoassay for the determination of 'total' activin-A concentrations in serum and follicular fluid. https://app.cochat.ai/papers/10.1677/joe.0.1480267
The paper
Knight, P. G., Muttukrishna, S., & Groome, N. P. (1996). Development and application of a two-site enzyme immunoassay for the determination of 'total' activin-A concentrations in serum and follicular fluid. Journal of Endocrinology. https://doi.org/10.1677/joe.0.1480267

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.