CoChat

Increased oxygen consumption rates in response to high glucose detected by a novel oxygen biosensor system in non-human primate and human islets

Open access
Wang, Wenjing, Upshaw, Lisa, Strong, D Michael, Robertson, R Paul, Reems, JoAnna · 2005 · Journal of Endocrinology
Cited by 88

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

In this study, we investigated the use of a novel oxygen biosensor system to detect changes in oxygen consumption rates (OCRs) by islets in response to glucose. Islets from non-human primate and human pancreata were seeded into an oxygen biosensor system microplate and exposed to basal (2.8 or 5.6 mM) or high (16.7 or 33.3 mM) glucose over either a long-term or a short-term culture. Our data clearly demonstrated that non-human primate islets cultured in high glucose conditions exhibited significant increases in OCRs over a 168 h extended culture period ( P <0.05), which indicates an accelerated rate of β-cell metabolism triggered by glucose over time. Significant increases in OCRs ( P <0.01) were also attained in both non-human primate and human islets exposed to high glucose conditions in a 120 min short-term incubation period. OCRs exhibited by human islets exposed to different glucose concentrations correlated with insulin secretion ( r 2 =0.7681, P <0.01). Moreover, the OCR stimulation index (i.e. OCR at high glucose/OCR at basal glucose) was significantly greater in human islets displaying high viabilities as opposed to islets exhibiting low viabilities ( P <0.05). Together these data demonstrate that this novel oxygen biosensor system documents significant increases in islet oxygen consumption upon acute and chronic exposure to high glucose concentrations. Importantly, this methodology rapidly and robustly detects changes in OCRs by islets in response to high glucose stimulation that correlate well with the metabolic activities and functional viability of islets and clearly delineates significant differences in OCR stimulation index between high and low viability human islets, and therefore may prove to be an effective approach for quickly assessing the functional viability of islets prior to transplantation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1677/joe.1.06092

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 88

Metadata

Authors
Wang, W., Upshaw, L., Strong, D. M., Robertson, R. P., & Reems, J.
Venue
Journal of Endocrinology
Published
2005-06
Volume
185
Issue
3
Pages
445-455
ISSN
  • 0022-0795 (ISSN-L)
  • 1479-6805
OpenAlex
W2163112129
Cited by
88
References
3
FWCI
5.29
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Increased oxygen consumption rates in response to high glucose detected by a novel oxygen biosensor system in non-human primate and human islets. https://app.cochat.ai/papers/10.1677/joe.1.06092
The paper
Wang, W., Upshaw, L., Strong, D. M., Robertson, R. P., & Reems, J. (2005). Increased oxygen consumption rates in response to high glucose detected by a novel oxygen biosensor system in non-human primate and human islets. Journal of Endocrinology. https://doi.org/10.1677/joe.1.06092

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.