Discrete and continuum analysis of localised deformation in sand using X-ray μCT and volumetric digital image correlation
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
The objective of this work was to observe and quantify the onset and evolution of localised deformation processes in sand with grain-scale resolution. The key element of the proposed approach is combining state-of-the-art X-ray micro tomography imaging with three-dimensional volumetric digital image correlation techniques. This allows not only the grain-scale details of a deforming sand specimen to be viewed, but also, and more importantly, the evolving three-dimensional displacement and strain fields throughout loading to be assessed. X-ray imaging and digital image correlation have been in the past applied individually to study sand deformation, but the combination of these two methods to study the kinematics of shear band formation at the grain scale is the first novel aspect of this work. Moreover, the authors have developed a completely original grain-scale volumetric digital image correlation method that permits the characterisation of the full kinematics (i.e. three-dimensional displacements and rotations) of all the individual sand grains in a specimen. The results obtained using the discrete volumetric digital image correlation confirm the importance of grain rotations associated with strain localisation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A discrete numerical model for granular assemblies
Cundall, P. A., & Strack, O. D. L. (1979) · Géotechnique · doi:10.1680/geot.1979.29.1.47 · Cited by 17,527 · cited 1×
“Since their initial development by Cundall & Strack (1979), discrete element methods have been gaining popularity as a numerical means to explore the mechanical behaviour of sand and other granular media at the scale of the grains.”
BackgroundApplications of digital-image-correlation techniques to experimental mechanics
Chu, T. C., Ranson, W. F., & Sutton, M. A. (1985) · Experimental Mechanics · doi:10.1007/bf02325092 · Cited by 2,236
Determination of displacements using an improved digital correlation method
Sutton, M., Wolters, W., Peters, W., Ranson, W., & McNeill, Sr. (1983) · Image and Vision Computing · doi:10.1016/0262-8856(83)90064-1 · Cited by 1,927
Digital volume correlation: Three-dimensional strain mapping using X-ray tomography
Bay, B. K., Smith, T. S., Fyhrie, D. P., & Saad, M. (1999) · Experimental Mechanics · doi:10.1007/bf02323555 · Cited by 941
Oda, M., & Kazama, H. (1998) · Géotechnique · doi:10.1680/geot.1998.48.4.465 · Cited by 548
Desrues, J., & Viggiani, G. (2004) · International Journal for Numerical and Analytical Methods in Geomechanics · doi:10.1002/nag.338 · Cited by 520
Self-citationA three-dimensional digital image correlation technique for strain measurements in microstructures
Verhulp, E. E., van Rietbergen, B., & Huiskes, R. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2003.12.036 · Cited by 325
3-D computer vision in experimental mechanics
Orteu, J. (2008) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2007.11.009 · Cited by 300
Methods and applications of digital volume correlation
Bay, B. K. (2008) · The Journal of Strain Analysis for Engineering Design · doi:10.1243/03093247jsa436 · Cited by 285
Grain-scale processes governing shear band initiation and evolution in sands
Rechenmacher, A. L. (2005) · Journal of the Mechanics and Physics of Solids · doi:10.1016/j.jmps.2005.08.009 · Cited by 229
Cited by
Cnudde, V., & Boone, M. N. (2013) · Earth-Science Reviews · doi:10.1016/j.earscirev.2013.04.003 · Cited by 1,572
Maire, E., & Withers, P. J. (2014) · International Materials Reviews · doi:10.1179/1743280413y.0000000023 · Cited by 1,374
An investigation of single sand particle fracture using X-ray micro-tomography
Zhao, B., Wang, J., Coop, M. R., Viggiani, G., & JIANG, M. (2015) · Géotechnique · doi:10.1680/geot.4.p.157 · Cited by 360
Self-citationNon-invasive characterization of particle morphology of natural sands
Fonseca, J., O’Sullivan, C., Coop, M. R., & Lee, P. D. (2012) · Soils and Foundations · doi:10.1016/j.sandf.2012.07.011 · Cited by 352
Digital Volume Correlation: Review of Progress and Challenges
Buljac, A., Jailin, C., Mendoza, A., Neggers, J., Taillandier-Thomas, T., Bouterf, A., Smaniotto, B., Hild, F., & Roux, S. (2018) · Experimental Mechanics · doi:10.1007/s11340-018-0390-7 · Cited by 305
Zhou, B., Wang, J., & Zhao, B. (2015) · Engineering Geology · doi:10.1016/j.enggeo.2014.11.009 · Cited by 270
Multiscale X-ray tomography of cementitious materials: A review
Brisard, S., Serdar, M., & Monteiro, P. J. M. (2020) · Cement and Concrete Research · doi:10.1016/j.cemconres.2019.105824 · Cited by 260
Mollon, G., & Zhao, J. (2014) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2014.06.022 · Cited by 247
“Possible solutions may be provided with the recent progress in X-ray computed micro-tomography and particle tracking algorithms [33].”
Methodspam: Software for Practical Analysis of Materials
Stamati, O., Andò, E., Roubin, E., Cailletaud, R., Wiebicke, M., Pinzon, G., Couture, C., Hurley, R., Caulk, R., Caillerie, D., et al. (2020) · Journal of Open Source Software · doi:10.21105/joss.02286 · Cited by 242
“Currently, the most-used scripts are related to image correlation: • spam-ldic and spam-regularStrain : A “local” image correlation script, working for series of greyscale 2D or 3D images where kinematics are measured on independent points spread on a regular grid, accompanied by a strain computation script. spam-ldic…”
Self-citationFourier–Voronoi-based generation of realistic samples for discrete modelling of granular materials
Mollon, G., & Zhao, J. (2012) · Granular Matter · doi:10.1007/s10035-012-0356-x · Cited by 235
Generating realistic 3D sand particles using Fourier descriptors
Mollon, G., & Zhao, J. (2013) · Granular Matter · doi:10.1007/s10035-012-0380-x · Cited by 171
Response of granular media to rapid penetration
Omidvar, M., Iskander, M., & Bless, S. (2014) · International Journal of Impact Engineering · doi:10.1016/j.ijimpeng.2013.12.004 · Cited by 161
Zhou, B., & Wang, J. (2017) · International Journal for Numerical and Analytical Methods in Geomechanics · doi:10.1002/nag.2548 · Cited by 160
Discrete element modeling of crushable sands considering realistic particle shape effect
Fu, R., Hu, X., & Zhou, B. (2017) · Computers and Geotechnics · doi:10.1016/j.compgeo.2017.07.016 · Cited by 160
Metadata
- Authors
- HALL, S. A., BORNERT, M., DESRUES, J., PANNIER, Y., LENOIR, N., VIGGIANI, G., & BéSUELLE, P.
- Venue
- Géotechnique
- Publisher
- Emerald
- Published
- 2010-05
- Volume
- 60
- Issue
- 5
- Pages
- 315-322
- ISSN
- 0016-8505 (ISSN-L)
- 1751-7656
- OpenAlex
- W2107566402
- Cited by
- 568
- References
- 12
- FWCI
- 80.40
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.