Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 285

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Time-Dependent Associations between Iron and Mortality in Hemodialysis Patients

Open access
Kalantar-Zadeh, Kamyar, Regidor, Deborah L., McAllister, Charles J., Michael, Beckie, Warnock, David G.·2005·Journal of the American Society of Nephrology

Abstract

The independent association between the indices of iron stores or administered intravenous iron, both of which vary over time, and survival in patients who are on maintenance hemodialysis (MHD) is not clear. It was hypothesized that the observed associations between moderately high levels of three iron markers (serum ferritin, iron, and iron saturation ratio) or administered intravenous iron and all-cause and cardiovascular death is due to the time-varying confounding effect of malnutrition-inflammation-cachexia syndrome (MICS). Time-dependent Cox regression models were examined using prospectively collected data of the 2-yr (July 2001 to June 2003) historical cohort of 58,058 MHD patients from virtually all DaVita dialysis clinics in the United States. After time-dependent and multivariate adjustment for case mix, administered intravenous iron and erythropoietin doses, and available surrogates of MICS, serum ferritin levels between 200 and 1200 ng/ml (reference 100 to 199 ng/ml), serum iron levels between 60 and 120 microg/ml (reference 50 to 59 microg/ml), and iron saturation ratio between 30 and 50% (reference 45 to 50%) were associated with the lowest all-cause and cardiovascular death risks. Compared with those who did not receive intravenous iron, administered intravenous iron up to 400 mg/mo was associated with improved survival, whereas doses >400 mg/mo tended to be associated with higher death rates. The association between serum ferritin levels >800 ng/ml and mortality in MHD patients seems to be due mostly to the confounding effects of MICS. For ascertaining whether the observed associations between moderate doses of administered intravenous iron and improved survival are causal or due to selection bias by indication, clinical trials are warranted.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1681/asn.2005040423

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 285

Metadata

Authors
Kalantar-Zadeh, K., Regidor, D. L., McAllister, C. J., Michael, B., & Warnock, D. G.
Venue
Journal of the American Society of Nephrology
Published
2005-10
Volume
16
Issue
10
Pages
3070-3080
ISSN
1046-6673 (ISSN-L)
OpenAlex
W2138609117
Cited by
285
References
1
FWCI
9.28
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Time-Dependent Associations between Iron and Mortality in Hemodialysis Patients. https://app.cochat.ai/papers/10.1681/asn.2005040423
The paper
Kalantar-Zadeh, K., Regidor, D. L., McAllister, C. J., Michael, B., & Warnock, D. G. (2005). Time-Dependent Associations between Iron and Mortality in Hemodialysis Patients. Journal of the American Society of Nephrology. https://doi.org/10.1681/asn.2005040423

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.