Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 270

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Efficient Removal of Immunoglobulin Free Light Chains by Hemodialysis for Multiple Myeloma: In Vitro and In Vivo Studies

Open access
Hutchison, Colin A., Cockwell, Paul, Reid, Steven, Chandler, Katie, Mead, Graham P., Harrison, John, Hattersley, John, Evans, Neil D., Chappell, Mike J., Cook, Mark, Goehl, Hermann, Storr, Markus, Bradwell, Arthur R.·2007·Journal of the American Society of Nephrology

Abstract

Of patients with newly diagnosed multiple myeloma, approximately 10% have dialysis-dependent acute renal failure, with cast nephropathy, caused by monoclonal free light chains (FLC). Of these, 80 to 90% require long-term renal replacement therapy. Early treatment by plasma exchange reduces serum FLC concentrations, but randomized, controlled trials have shown no evidence of renal recovery. This outcome can be explained by the low efficiency of the procedure. A model of FLC production, distribution, and metabolism in patients with myeloma indicated that plasma exchange might remove only 25% of the total amount during a 3-wk period. For increasing FLC removal, extended hemodialysis with a protein-leaking dialyzer was used. In vitro studies indicated that the Gambro HCO 1100 dialyzer was the most efficient of seven tested. Model calculations suggested that it might remove 90% of FLC during 3 wk. This dialyzer then was evaluated in eight patients with myeloma and renal failure. Serum FLC reduced by 35 to 70% within 2 hr, but reduction rates slowed as extravascular re-equilibration occurred. FLC concentrations rebounded on successive days unless chemotherapy was effective. Five additional patients with acute renal failure that was caused by cast nephropathy then were treated aggressively, and three became dialysis independent. A total of 1.7 kg of FLC was removed from one patient during 6 wk. Extended hemodialysis with the Gambro HCO 1100 dialyzer allowed continuous, safe removal of FLC in large amounts. Proof of clinical value now will require larger studies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1681/asn.2006080821

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 270

Metadata

Authors
Hutchison, C. A., Cockwell, P., Reid, S., Chandler, K., Mead, G. P., Harrison, J., Hattersley, J., Evans, N. D., Chappell, M. J., Cook, M., Goehl, H., Storr, M., & Bradwell, A. R.
Venue
Journal of the American Society of Nephrology
Published
2007-03
Volume
18
Issue
3
Pages
886-895
ISSN
1046-6673 (ISSN-L)
OpenAlex
W2149024804
Cited by
270
References
1
FWCI
11.92
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Efficient Removal of Immunoglobulin Free Light Chains by Hemodialysis for Multiple Myeloma: In Vitro and In Vivo Studies. https://app.cochat.ai/papers/10.1681/asn.2006080821
The paper
Hutchison, C. A., Cockwell, P., Reid, S., Chandler, K., Mead, G. P., Harrison, J., Hattersley, J., Evans, N. D., Chappell, M. J., Cook, M., Goehl, H., Storr, M., & Bradwell, A. R. (2007). Efficient Removal of Immunoglobulin Free Light Chains by Hemodialysis for Multiple Myeloma: In Vitro and In Vivo Studies. Journal of the American Society of Nephrology. https://doi.org/10.1681/asn.2006080821

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.