The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Measured GFR as a Confirmatory Test for Estimated GFR
Abstract
Clinical assessment of kidney function is central to the practice of medicine. GFR is widely accepted as the best index of kidney function in health and disease, and accurate values are required for optimal decision making. Estimated GFR based on serum creatinine is now widely reported by clinical laboratories, and in most circumstances, estimated GFR is sufficient for clinical decision making. GFR estimates may be inaccurate in the non-steady state and in people in whom non-GFR determinants differ greatly from those in whom the estimating equation was developed. If GFR estimates are likely inaccurate or if decisions based on inaccurate estimates may have adverse consequences, a measured GFR is an important confirmatory test. Endogenous creatinine clearance is the most common method used to measure GFR in clinical practice but may be difficult to obtain or fraught with error. We review methods for GFR measurement using urinary and plasma clearance of exogenous filtration markers and focus on urinary clearance of iothalamate and plasma clearance of iohexol compared with inulin clearance. We suggest plasma clearance of nonradioactive markers be more widely implemented in clinical settings. Further research is necessary on the impact of the use of measured GFR as a confirmatory test.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A New Equation to Estimate Glomerular Filtration Rate
Levey, A. S., Stevens, L. A., Schmid, C. H., Zhang, Y. (., Castro, A. F., Feldman, H. I., Kusek, J. W., Eggers, P., Van Lente, F., Greene, T., et al. (2009) · Annals of Internal Medicine · doi:10.7326/0003-4819-150-9-200905050-00006 · Cited by 25,603
Self-citationAssessing Kidney Function — Measured and Estimated Glomerular Filtration Rate
Stevens, L. A., Coresh, J., Greene, T., & Levey, A. S. (2006) · New England Journal of Medicine · doi:10.1056/nejmra054415 · Cited by 2,952
Self-citation
Cited by
Levey, A. S., & Coresh, J. (2012) · The Lancet · doi:10.1016/s0140-6736(11)60178-5 · Cited by 1,841
Self-citationGlomerular hyperfiltration in diabetes: mechanisms, clinical significance, and treatment
Tonneijck, L., Muskiet, M. H. A., Smits, M. M., van Bommel, E. J., Heerspink, H. J. L., van Raalte, D. H., & Joles, J. A. (2017) · Journal of the American Society of Nephrology · doi:10.1681/asn.2016060666 · Cited by 887
Two Novel Equations to Estimate Kidney Function in Persons Aged 70 Years or Older
Schaeffner, E. S., Ebert, N., Delanaye, P., Frei, U., Gaedeke, J., Jakob, O., Kuhlmann, M. K., Schuchardt, M., Tölle, M., Ziebig, R., et al. (2012) · Annals of Internal Medicine · doi:10.7326/0003-4819-157-7-201210020-00003 · Cited by 632
Matzke, G. R., Aronoff, G. R., Atkinson, A. J., Bennett, W. M., Decker, B. S., Eckardt, K.-U., Golper, T., Grabe, D. W., Kasiske, B., Keller, F., et al. (2011) · Kidney International · doi:10.1038/ki.2011.322 · Cited by 462
Floege, J., Barbour, S. J., Cattran, D. C., Hogan, J. J., Nachman, P. H., Tang, S. C. W., Wetzels, J. F. M., Cheung, M., Wheeler, D. C., Winkelmayer, W. C., et al. (2019) · Kidney International · doi:10.1016/j.kint.2018.10.018 · Cited by 263
Metadata
- Authors
- Stevens, L. A., & Levey, A. S.
- Venue
- Journal of the American Society of Nephrology
- Published
- 2009-11
- Volume
- 20
- Issue
- 11
- Pages
- 2305-2313
- ISSN
- 1046-6673 (ISSN-L)
- OpenAlex
- W2156486561
- Cited by
- 602
- References
- 2
- FWCI
- 20.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Measured GFR as a Confirmatory Test for Estimated GFR. https://app.cochat.ai/papers/10.1681/asn.2009020171
- The paper
- Stevens, L. A., & Levey, A. S. (2009). Measured GFR as a Confirmatory Test for Estimated GFR. Journal of the American Society of Nephrology. https://doi.org/10.1681/asn.2009020171
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.