The DOI matches its Crossref record.
Ion-Exchange Resins for the Treatment of Hyperkalemia: Are They Safe and Effective?
Abstract
Sodium polystyrene sulfonate (SPS), an ion-exchange resin designed to bind potassium in the colon, was approved in 1958 as a treatment for hyperkalemia by the US Food and Drug Administration, 4 years before drug manufacturers were required to prove the effectiveness and safety of their drugs. In September 2009, citing reports of colonic necrosis, the Food and Drug Administration issued a warning advising against concomitant administration of sorbitol, an osmotic cathartic used to prevent SPS-induced fecal impaction and to speed delivery of resin to the colon, with the powdered resin; however, a premixed suspension of SPS in sorbitol, the only preparation stocked by many hospital pharmacies, is prescribed routinely for treatment of hyperkalemia. We can find no convincing evidence that SPS increases fecal potassium losses in experimental animals or humans and no evidence that adding sorbitol to the resin increases its effectiveness as a treatment for hyperkalemia. There is growing concern, however, that suspensions of SPS in sorbitol can be harmful. It would be wise to exhaust other alternatives for managing hyperkalemia before turning to these largely unproven and potentially harmful therapies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Sodium Zirconium Cyclosilicate in Hyperkalemia
Packham, D. K., Rasmussen, H. S., Lavin, P. T., El-Shahawy, M. A., Roger, S. D., Block, G., Qunibi, W., Pergola, P., & Singh, B. (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1411487 · Cited by 506
Clase, C. M., Carrero, J.-J., Ellison, D. H., Grams, M. E., Hemmelgarn, B. R., Jardine, M. J., Kovesdy, C. P., Kline, G. A., Lindner, G., Obrador, G. T., et al. (2020) · Kidney International · doi:10.1016/j.kint.2019.09.018 · Cited by 498
Bakris, G. L., Pitt, B., Weir, M. R., Freeman, M. W., Mayo, M. R., Garza, D., Stasiv, Y., Zawadzki, R., Berman, L., & Bushinsky, D. A. (2015) · JAMA · doi:10.1001/jama.2015.7446 · Cited by 441
Lipid Nanoparticle Formulations for Enhanced Co-delivery of siRNA and mRNA
Ball, R. L., Hajj, K. A., Vizelman, J., Bajaj, P., & Whitehead, K. A. (2018) · Nano Letters · doi:10.1021/acs.nanolett.8b01101 · Cited by 313
Association between Serum Potassium and Outcomes in Patients with Reduced Kidney Function
Luo, J., Brunelli, S. M., Jensen, D. E., & Yang, A. (2016) · Clinical Journal of the American Society of Nephrology · doi:10.2215/cjn.01730215 · Cited by 288
Metadata
- Authors
- Sterns, R. H., Rojas, M., Bernstein, P., & Chennupati, S.
- Venue
- Journal of the American Society of Nephrology
- Published
- 2010-05
- Volume
- 21
- Issue
- 5
- Pages
- 733-735
- ISSN
- 1046-6673 (ISSN-L)
- OpenAlex
- W2101879409
- Cited by
- 303
- References
- 0
- FWCI
- 12.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ion-Exchange Resins for the Treatment of Hyperkalemia: Are They Safe and Effective? https://app.cochat.ai/papers/10.1681/asn.2010010079
- The paper
- Sterns, R. H., Rojas, M., Bernstein, P., & Chennupati, S. (2010). Ion-Exchange Resins for the Treatment of Hyperkalemia: Are They Safe and Effective? Journal of the American Society of Nephrology. https://doi.org/10.1681/asn.2010010079
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.