Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 237

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Randomized Clinical Trial of Dialysate Cooling and Effects on Brain White Matter

Open access
Eldehni, Mohamed T., Odudu, Aghogho, McIntyre, Christopher W. · 2015 · Journal of the American Society of Nephrology

Abstract

Hemodialysis is associated with significant circulatory stress that could produce recurrent and cumulative ischemic insults to multiple organs, such as the brain. We aimed to characterize hemodialysis-induced brain injury by longitudinally studying the effects of hemodialysis on brain white matter microstructure and further examine if the use of cooled dialysate could provide protection against hemodialysis-associated brain injury. In total, 73 patients on incident hemodialysis starting within 6 months were randomized to dialyze with a dialysate temperature of either 37°C or 0.5°C below the core body temperature and followed up for 1 year. Brain white matter microstructure was studied by diffusion tensor magnetic resonance imaging at baseline and follow-up (38 patients available for paired analysis). Intradialytic hemodynamic stress was quantified using the extrema points analysis model. Patients on hemodialysis exhibited a pattern of ischemic brain injury (increased fractional anisotropy and reduced radial diffusivity). Cooled dialysate improved hemodynamic tolerability, and changes in brain white matter were associated with hemodynamic instability (higher mean arterial pressure extrema points frequencies were associated with higher fractional anisotropy [peak r=0.443, P<0.03] and lower radial diffusivity [peak r=-0.439, P<0.02]). Patients who dialyzed at 0.5°C below core body temperature exhibited complete protection against white matter changes at 1 year. Our data suggest that hemodialysis results in significant brain injury and that improvement in hemodynamic tolerability achieved by using cooled dialysate is effective at abrogating these effects. This intervention can be delivered without additional cost and is universally applicable.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1681/asn.2013101086

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 237

Metadata

Authors
Eldehni, M. T., Odudu, A., & McIntyre, C. W.
Venue
Journal of the American Society of Nephrology
Published
2015-04
Volume
26
Issue
4
Pages
957-965
ISSN
1046-6673 (ISSN-L)
OpenAlex
W2097269110
Cited by
237
References
3
FWCI
14.06
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Randomized Clinical Trial of Dialysate Cooling and Effects on Brain White Matter. https://app.cochat.ai/papers/10.1681/asn.2013101086
The paper
Eldehni, M. T., Odudu, A., & McIntyre, C. W. (2015). Randomized Clinical Trial of Dialysate Cooling and Effects on Brain White Matter. Journal of the American Society of Nephrology. https://doi.org/10.1681/asn.2013101086

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.