Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 203

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Prognostic Value of Ultrasonographic Measurement of Carotid Intima Media Thickness in Dialysis Patients

BENEDETTO, FRANCESCO ANTONIO, MALLAMACI, FRANCESCA, TRIPEPI, GIOVANNI, ZOCCALI, CARMINE · 2001 · Journal of the American Society of Nephrology

Abstract

High-resolution carotid ultrasonography is considered a fundamental technique for the investigation of the vascular system. However, it is still very unclear whether ultrasonographic studies of carotid arteries are useful for the prediction of cardiovascular events in patients with end-stage renal disease. The prediction power of carotid ultrasonography for all-cause and cardiovascular mortality was tested in a cohort of 138 patients receiving chronic dialysis treatment (91 receiving hemodialysis treatment and 47 receiving continuous ambulatory peritoneal dialysis treatment; follow-up, 29.8 +/- 15.0 mo), and the relationship between this parameter and alterations in left ventricular mass (LVM) and geometry was examined. On univariate analysis, intima media thickness (IMT) was directly related to LVM as well as to the absolute and relative thicknesses of LV walls but independent of LV end-diastolic volume. Data analysis based on LV geometry patterns revealed that patients with concentric hypertrophy were those with the highest IMT. The internal diameter of the common carotid artery (DCCA) was also related to concentric hypertrophy, but the strength of this relationship was of borderline significance (P = 0.06). During the follow-up period, 63 patients died: 32 (51%) of them of cardiovascular causes. IMT was significantly higher (P = 0.006) in patients who died of cardiovascular causes (1.10 +/- 0.21 mm) than in patients who survived (0.99 +/- 0.24 mm), In a Cox regression model, this parameter turned out to be an independent predictor of cardiovascular death, and it retained an independent effect in a model that included LVM. Treatment modality failed to independently predict this outcome. The risk of cardiovascular death was progressively higher from the first IMT tertile onward. DCCA failed to predict cardiovascular outcomes. IMT in dialysis patients is associated with LV concentric hypertrophy and is an independent predictor of cardiovascular death. IMT may be usefully applied for risk stratification in the dialysis population.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1681/asn.v12112458

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 203

Metadata

Authors
BENEDETTO, F. A., MALLAMACI, F., TRIPEPI, G., & ZOCCALI, C.
Venue
Journal of the American Society of Nephrology
Published
2001-11
Volume
12
Issue
11
Pages
2458-2464
ISSN
1046-6673 (ISSN-L)
OpenAlex
W2153728593
Cited by
203
References
2
FWCI
5.44
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Prognostic Value of Ultrasonographic Measurement of Carotid Intima Media Thickness in Dialysis Patients. https://app.cochat.ai/papers/10.1681/asn.v12112458
The paper
BENEDETTO, F. A., MALLAMACI, F., TRIPEPI, G., & ZOCCALI, C. (2001). Prognostic Value of Ultrasonographic Measurement of Carotid Intima Media Thickness in Dialysis Patients. Journal of the American Society of Nephrology. https://doi.org/10.1681/asn.v12112458

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.