The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Second generation logarithmic estimates of single-pool variable volume Kt/V: an analysis of error.
Abstract
The original formula proposed to estimate variable-volume single-pool (VVSP) Kt/V was Kt/V = -In(R - 0.008 * t - f * UF/W), where in the Kt/V range of 0.7 to 1.3, f = 1.0 (* denotes multiplication). This formula tends to overestimate Kt/V as the Kt/V increases above 1.3. Because higher Kt/V values are now commonly delivered, the validity of both the urea generation term (0.008 * f) and correction for UF/W were explored by solving VVSP equations for simulated hemodialysis situations, with Kt/V ranging from 0.6 to 2.6. The analysis led to the development of a second-generation formula, namely: Kt/V = -In(R - 0.008 * t) + (4-3.5 * R) * UF/W. The first and second generation formulas were then used to estimate the modeled VVSP Kt/V in 500 modeling sessions in which the Kt/V ranged widely from 0.7 to 2.1. An analysis of error showed that this second-generation formula eliminated the overestimation of Kt/V in the high ranges found with the first-generation formula. Also, total error (absolute value percent error + 2 SD) was reduced with the second-generation formula. These results led to the proposal of a new formula that can be used for a very wide range of delivered Kt/V.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Hemodialysis prescription and delivery in a metropolitan community
Delmez, J. A., & Windus, D. W. (1992) · Kidney International · doi:10.1038/ki.1992.155 · Cited by 65
Cited by
KDOQI Clinical Practice Guideline for Hemodialysis Adequacy: 2015 Update
Daugirdas, J. T., Depner, T. A., Inrig, J., Mehrotra, R., Rocco, M. V., Suri, R. S., Weiner, D. E., Greer, N., Ishani, A., MacDonald, R., et al. (2015) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2015.07.015 · Cited by 1,320
Self-citationGANESH, S. K., STACK, A. G., LEVIN, N. W., HULBERT-SHEARON, T., & PORT, F. K. (2001) · Journal of the American Society of Nephrology · doi:10.1681/asn.v12102131 · Cited by 1,204
Boaz, M., Smetana, S., Weinstein, T., Matas, Z., Gafter, U., Iaina, A., Knecht, A., Weissgarten, Y., Brunner, D., Fainaru, M., et al. (2000) · The Lancet · doi:10.1016/s0140-6736(00)02783-5 · Cited by 1,025
Daily Hemodialysis and the Outcome of Acute Renal Failure
Schiffl, H., Lang, S. M., & Fischer, R. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa010877 · Cited by 862
Fouque, D., Vennegoor, M., Ter Wee, P., Wanner, C., Basci, A., Canaud, B., Haage, P., Konner, K., Kooman, J., Martin-Malo, A., et al. (2007) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfm020 · Cited by 712
Metadata
- Authors
- Daugirdas, J. T.
- Venue
- Journal of the American Society of Nephrology
- Published
- 1993-11
- Volume
- 4
- Issue
- 5
- Pages
- 1205-1213
- ISSN
- 1046-6673 (ISSN-L)
- OpenAlex
- W2143345898
- Cited by
- 1,447
- References
- 2
- FWCI
- 10.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.