Plasma clearance of nonradioactive iohexol as a measure of glomerular filtration rate.
Abstract
Renal clearance of inulin is the best available indicator of GFR but cannot be used routinely for clinical purposes and is also difficult to perform for clinical investigation when repeated measurements are required. The aim of this study was to find a reliable alternative to inulin clearance that would allow one to avoid the use of radioactivity and problems related to the continuous infusion of the marker. The plasma clearance of unlabeled iohexol, a nonionic contrast agent, was used. Forty-one patients (creatinine clearance 6 to 160 mL/min per 1.73 m2) underwent simultaneous measurements of renal clearance of inulin and plasma clearance of iohexol. Iohexol was given as a single iv dose, and blood samples were drawn up to 600 min after the administration. Iohexol concentrations (by HPLC) were analyzed by a two-compartment, open-model system. A highly significant correlation between the plasma clearance of iohexol and the renal clearance of inulin over a wide range of GFR values was found. By analyzing the data with a simplified method that uses a one-compartment model corrected with the Bröchner-Mortensen formula, an excellent correlation with the inulin clearance was also observed. When only patients with moderate to severe renal failure were considered, a significant correlation between the two methods was found. A further comparison between GFR determined with iohexol and iopromide, a new low-osmolarity, low-viscosity contrast medium, was also performed in a subgroup of patients.(ABSTRACT TRUNCATED AT 250 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Cited by
Ruggenenti, P., Perna, A., Gherardi, G., Garini, G., Zoccali, C., Salvadori, M., Scolari, F., Schena, F. P., & Remuzzi, G. (1999) · The Lancet · doi:10.1016/s0140-6736(98)10363-x · Cited by 910
Self-citationRuggenenti, P., Abbate, M., Ruggiero, B., Rota, S., Trillini, M., Aparicio, C., Parvanova, A., Petrov Iliev, I., Pisanu, G., Perna, A., et al. (2017) · Diabetes · doi:10.2337/db16-0607 · Cited by 95
Self-citation
Metadata
- Authors
- Gaspari, F., Perico, N., Ruggenenti, P., Mosconi, L., Amuchastegui, C. S., Guerini, E., Daina, E., & Remuzzi, G.
- Venue
- Journal of the American Society of Nephrology
- Published
- 1995-08
- Volume
- 6
- Issue
- 2
- Pages
- 257-263
- ISSN
- 1046-6673 (ISSN-L)
- OpenAlex
- W2136871445
- Cited by
- 375
- References
- 1
- FWCI
- 6.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Plasma clearance of nonradioactive iohexol as a measure of glomerular filtration rate. https://app.cochat.ai/papers/10.1681/asn.v62257
- The paper
- Gaspari, F., Perico, N., Ruggenenti, P., Mosconi, L., Amuchastegui, C. S., Guerini, E., Daina, E., & Remuzzi, G. (1995). Plasma clearance of nonradioactive iohexol as a measure of glomerular filtration rate. Journal of the American Society of Nephrology. https://doi.org/10.1681/asn.v62257
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.