Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 159

The DOI matches its Crossref record.

Staphylococcus aureus prophylaxis in hemodialysis patients using central venous catheter: effect of mupirocin ointment.

Sesso, R, Barbosa, D, Leme, I L, Sader, H, Canziani, M E, Manfredi, S, Draibe, S, Pignatari, A C·1998·Journal of the American Society of Nephrology

Abstract

Central venous catheterization is a common technique to establish rapid and temporary access for hemodialysis. However, it is a known risk factor for Staphylococcus aureus infection and bacteremia. Mupirocin is a topical antibiotic with high in vitro anti-staphylococcal activity. A randomized prospective trial was conducted to assess the effectiveness of mupirocin ointment in the prevention of Staphylococcus aureus skin and catheter colonization, and episodes of bacteremia in 136 end-stage renal disease patients. Of these, 67 received skin disinfection at the venous catheter insertion site with povidone iodine (control group), and 69 received the same treatment followed by application of 2% mupirocin ointment at the cannula site after catheter placement and at the end of each dialysis session. Patients were followed until catheter removal and were monitored for the development of Staphylococcus aureus skin/catheter colonization and episodes of bacteremia. Median duration of catheter use was greater in the mupirocin than in the control group (37 versus 20 d, P < 0.01). Patients in the mupirocin group had a significantly lower rate of Staphylococcus aureus isolation from the pericatheter skin (1.76 per 1000 versus 14.27 per 1000 patient-days, P < 0.001) and from the catheter surface (3.17 per 1000 versus 14.27 per 1000 patient-days, P < 0.001). The proportion of patients with Staphylococcus aureus skin infection at the insertion site was lower in the mupirocin group (4.3% versus 23.9%, P = 0.001). Staphylococcus aureus-associated bacteremia was observed in 17 patients (two in the mupirocin group [0.71 episodes per 1000 patient-days] and 15 in the control group [8.92 per 1000 patient-days], P < 0.001). The hazard ratio of developing Staphylococcus aureus bacteremia was 7.2 (95% confidence interval, 1.6 to 31.6) times greater in patients not receiving mupirocin. Mupirocin applied to the insertion site significantly reduces the risk of Staphylococcus aureus skin and catheter colonization, exit-site infection, and Staphylococcus aureus bacteremia in hemodialysis patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1681/asn.v961085

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 159

Metadata

Authors
Sesso, R., Barbosa, D., Leme, I. L., Sader, H., Canziani, M. E., Manfredi, S., Draibe, S., & Pignatari, A. C.
Venue
Journal of the American Society of Nephrology
Published
1998-06
Volume
9
Issue
6
Pages
1085-1092
ISSN
1046-6673 (ISSN-L)
OpenAlex
W2131828096
Cited by
159
References
0
FWCI
7.75
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Staphylococcus aureus prophylaxis in hemodialysis patients using central venous catheter: effect of mupirocin ointment. https://app.cochat.ai/papers/10.1681/asn.v961085
The paper
Sesso, R., Barbosa, D., Leme, I. L., Sader, H., Canziani, M. E., Manfredi, S., Draibe, S., & Pignatari, A. C. (1998). Staphylococcus aureus prophylaxis in hemodialysis patients using central venous catheter: effect of mupirocin ointment. Journal of the American Society of Nephrology. https://doi.org/10.1681/asn.v961085

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.