The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Comparison of the 2-, 6-, and 12-minute walk tests in patients with stroke
Abstract
This study assessed inter- and intrarater reliability and sensitivity to change of the 2-, 6-, and 12-minute walk tests following stroke. A convenience sample of patients enrolled in an inpatient stroke rehabilitation program participated in the standardization protocol. The 2-, 6-, and 12-minute walk tests were performed and inter- and intrarater reliability and responsiveness to change assessed. The interrater intraclass correlation coefficients (ICCs) for the 2-, 6-, and 12-minute walk tests were, respectively, 0.85, 0.78, and 0.68 (p < 0.0007 for each). The intrarater ICCs were 0.85, 0.74, and 0.71 (p < 0.0003 for each). Responsiveness to change as measured by standardized response mean (SRM) scores was, respectively, 1.34, 1.52, and 1.90 (F = 24.24, p < 0.001). Pearson correlations for the 2-, 6-, and 12-minute walk tests by the same rater on the same day were 2 versus 6 minutes, r = 0.997; 2 versus 12 minutes, r = 0.993; and 6 versus 12 minutes, r = 0.994 (p < 0.0001 for each). The 2-, 6-, and 12-minute walk tests show acceptable inter- and intrarater reliability and high intertest correlations when they are used for the assessment of walking following stroke. The SRM statistic indicates that the 12-minute walk test is the most responsive to change.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Two-, six-, and 12-minute walking tests in respiratory disease.
Butland, R. J., Pang, J., Gross, E. R., Woodcock, A. A., & Geddes, D. M. (1982) · BMJ · doi:10.1136/bmj.284.6329.1607 · Cited by 1,668
Clinical Gait Assessment in the Neurologically Impaired
Holden, M. K., Gill, K. M., Magliozzi, M. R., Nathan, J., & Piehl-Baker, L. (1984) · Physical Therapy · doi:10.1093/ptj/64.1.35 · Cited by 1,499
Cited by
Vision assessment using the NIH Toolbox
Varma, R., McKean-Cowdin, R., Vitale, S., Slotkin, J., & Hays, R. D. (2013) · Neurology · doi:10.1212/wnl.0b013e3182876e0a · Cited by 1,178
Tyson, S., & Connell, L. (2009) · Clinical Rehabilitation · doi:10.1177/0269215509339004 · Cited by 364
Hiengkaew, V., Jitaree, K., & Chaiyawat, P. (2012) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2012.01.014 · Cited by 337
Bohannon, R. W., Wang, Y.-C., & Gershon, R. C. (2015) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2014.10.006 · Cited by 259
Motor assessment using the NIH Toolbox
Reuben, D. B., Magasi, S., McCreath, H. E., Bohannon, R. W., Wang, Y.-C., Bubela, D. J., Rymer, W. Z., Beaumont, J., Rine, R. M., Lai, J.-S., et al. (2013) · Neurology · doi:10.1212/wnl.0b013e3182872e01 · Cited by 254
Metadata
- Authors
- Kosak, M., & Smith, T.
- Venue
- The Journal of Rehabilitation Research and Development
- Published
- 2004
- Volume
- 41
- Issue
- 1
- Pages
- 103
- ISSN
- 0742-3241 (ISSN-L)
- 0748-7711
- OpenAlex
- W2113835821
- Cited by
- 250
- References
- 2
- FWCI
- 2.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.