The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Kinematic and kinetic comparisons of transfemoral amputee gait using C-Leg and Mauch SNS prosthetic knees
Abstract
The C-Leg (Otto Bock, Duderstadt, Germany) is a microprocessor-controlled prosthetic knee that may enhance amputee gait. This intrasubject randomized study compared the gait biomechanics of transfemoral amputees wearing the C-Leg with those wearing a common noncomputerized prosthesis, the Mauch SNS (Ossur, Reykjavik, Iceland). After subjects had a 3-month acclimation period with each prosthetic knee, typical gait biomechanical data were collected in a gait laboratory. At a controlled walking speed (CWS), peak swing phase knee-flexion angle decreased for the C-Leg group compared with the Mauch SNS group (55.2 degrees +/- 6.5 degrees vs 64.41 degrees +/- 5.8 degrees , respectively; p = 0.005); the C-Leg group was similar to control subjects' peak swing knee-flexion angle (56.0 degrees +/- 3.4 degrees ). Stance knee-flexion moment increased for the C-Leg group compared with the Mauch SNS group (0.142 +/- 0.05 vs 0.067 +/- 0.07 N"m, respectively; p = 0.01), but remained significantly reduced compared with control subjects (0.477 +/- 0.1 N"m). Prosthetic limb step length at CWS was less for the C-Leg group compared with the Mauch SNS group (0.66 +/- 0.04 vs 0.70 +/- 0.06 m, respectively; p = 0.005), which resulted in increased symmetry between limbs for the C-Leg group. Subjects also walked faster with the C-Leg versus the Mauch SNS (1.30 +/- 0.1 vs 1.21 +/- 0.1 m/s, respectively; p = 0.004). The C-Leg prosthetic limb vertical ground reaction force decreased compared with the Mauch SNS (96.3 +/- 4.7 vs 100.3 +/- 7.5 % body weight, respectively; p = 0.0092).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mixed-Effects Models in S and S-PLUS
(2001) · Technometrics · doi:10.1198/tech.2001.s574 · Cited by 9,278
Response of joints to impact loading — III
Radin, E. L., Parker, H. G., Pugh, J. W., Steinberg, R. S., Paul, I. L., & Rose, R. M. (1973) · Journal of Biomechanics · doi:10.1016/0021-9290(73)90037-7 · Cited by 619
Energy Generation and Absorption at the Ankle and Knee during Fast, Natural, and Slow Cadences
WINTER, D. A. (1983) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198305000-00021 · Cited by 579
Biomechanics of below-knee amputee gait
Winter, D. A., & Sienko, S. E. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90142-x · Cited by 521
Adjustments in gait symmetry with walking speed in trans-femoral and trans-tibial amputees
Nolan, L., Wit, A., Dudziñski, K., Lees, A., Lake, M., & Wychowañski, M. (2003) · Gait & Posture · doi:10.1016/s0966-6362(02)00066-8 · Cited by 454
Predicting peak kinematic and kinetic parameters from gait speed
Lelas, J. L., Merriman, G. J., Riley, P. O., & Kerrigan, D. C. (2003) · Gait & Posture · doi:10.1016/s0966-6362(02)00060-7 · Cited by 430
Energy expenditure and biomechanical characteristics of lower limb amputee gait:
Schmalz, T., Blumentritt, S., & Jarasch, R. (2002) · Gait & Posture · doi:10.1016/s0966-6362(02)00008-5 · Cited by 428
Issues of importance reported by persons with lower limb amputations and prostheses.
Legro, M. W., Reiber, G. E., del Aguila, M., Ajax, M. J., Boone, D. A., Larsen, J. A., Smith, D. G., & Sangeorzan, B. J. (1999) · PubMed · Cited by 310
A Clinical Comparison of Variable-Damping and Mechanically Passive Prosthetic Knee Devices
Johansson, J. L., Sherrill, D. M., Riley, P. O., Bonato, P., & Herr, H. (2005) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/01.phm.0000174665.74933.0b · Cited by 302
Prosthetic gait of unilateral transfemoral amputees: A kinematic study
Jaegers, S. M. H. J., Arendzen, J. H., & de Jongh, H. J. (1995) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(95)80528-1 · Cited by 293
Cited by
Active lower limb prosthetics: a systematic review of design issues and solutions
Windrich, M., Grimmer, M., Christ, O., Rinderknecht, S., & Beckerle, P. (2016) · BioMedical Engineering OnLine · doi:10.1186/s12938-016-0284-9 · Cited by 272
Metadata
- Authors
- Segal, A. D., Orendurff, M. S., Klute, G. K., McDowell, M. L., Pecoraro, J. A., Shofer, J., & Czerniecki, J. M.
- Venue
- The Journal of Rehabilitation Research and Development
- Published
- 2006
- Volume
- 43
- Issue
- 7
- Pages
- 857
- ISSN
- 0742-3241 (ISSN-L)
- 0748-7711
- OpenAlex
- W1990263710
- Cited by
- 286
- References
- 15
- FWCI
- 2.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Kinematic and kinetic comparisons of transfemoral amputee gait using C-Leg and Mauch SNS prosthetic knees. https://app.cochat.ai/papers/10.1682/jrrd.2005.09.0147
- The paper
- Segal, A. D., Orendurff, M. S., Klute, G. K., McDowell, M. L., Pecoraro, J. A., Shofer, J., & Czerniecki, J. M. (2006). Kinematic and kinetic comparisons of transfemoral amputee gait using C-Leg and Mauch SNS prosthetic knees. The Journal of Rehabilitation Research and Development. https://doi.org/10.1682/jrrd.2005.09.0147
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.