Construct validity of RT3 accelerometer: A comparison of level-ground and treadmill walking at self-selected speeds
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
This study examined differences in accelerometer output when subjects walked on level ground and on a treadmill. We asked 25 nondisabled participants to wear an RT3 triaxial accelerometer (StayHealthy, Inc; Monrovia, California) and walk at their "normal" and "brisk" walking speeds for 10 minutes. These activities were repeated on a treadmill using the individual speeds from level-ground walking on two occasions 1 week apart. Paired t-tests found a difference in RT3 accelerometer vector magnitude (VM) counts/min between the two walking speeds on both surfaces on days 1 and 2 (p < 0.001). Although we found no significant differences between VM counts/min on the two surfaces at normal and brisk speeds on days 1 and 2 (p > 0.05), we found wide limits of agreement between level ground and treadmill walking at both speeds. Measurement and discrimination of walking intensity employing RT3 accelerometer VM counts/min on the treadmill demonstrated reasonable validity and stability over two time points compared with level-ground walking.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Accelerometer Use in Physical Activity: Best Practices and Research Recommendations
WARD, D. S., EVENSON, K. R., VAUGHN, A., RODGERS, A. B., & TROIANO, R. P. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185292.71933.91 · Cited by 779
Cited by
Strath, S. J., Kaminsky, L. A., Ainsworth, B. E., Ekelund, U., Freedson, P. S., Gary, R. A., Richardson, C. R., Smith, D. T., & Swartz, A. M. (2013) · Circulation · doi:10.1161/01.cir.0000435708.67487.da · Cited by 1,029
Validity of Consumer-Based Physical Activity Monitors
LEE, J.-M., KIM, Y., & WELK, G. J. (2014) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000287 · Cited by 401
“Previous research (14, 17) has demonstrated clear limitations with the use of standard accelerometrybased, activity monitors for assessing energy expenditure under free-living conditions.”
BackgroundKim, Y., Beets, M. W., & Welk, G. J. (2012) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2011.12.001 · Cited by 186
Different Location of Triaxial Accelerometer and Different Energy Expenditures
Kim, D. Y., Jung, Y.-S., Park, R.-W., & Joo, N.-S. (2014) · Yonsei Medical Journal · doi:10.3349/ymj.2014.55.4.1145 · Cited by 34
Towards an understanding of physical activity in people with chronic low back pain
Griffin, D. W. (2013) · University of Limerick · doi:10.34961/7893 · Cited by 1
Metadata
- Authors
- Hendrick, P., Boyd, T., Low, O., Takarangi, K., Paterson, M., Claydon, L., & Milosavljevic, S.
- Venue
- The Journal of Rehabilitation Research and Development
- Published
- 2010
- Volume
- 47
- Issue
- 2
- Pages
- 157
- ISSN
- 0742-3241 (ISSN-L)
- 0748-7711
- OpenAlex
- W2141600032
- Cited by
- 24
- References
- 2
- FWCI
- 1.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Construct validity of RT3 accelerometer: A comparison of level-ground and treadmill walking at self-selected speeds. https://app.cochat.ai/papers/10.1682/jrrd.2009.04.0047
- The paper
- Hendrick, P., Boyd, T., Low, O., Takarangi, K., Paterson, M., Claydon, L., & Milosavljevic, S. (2010). Construct validity of RT3 accelerometer: A comparison of level-ground and treadmill walking at self-selected speeds. The Journal of Rehabilitation Research and Development. https://doi.org/10.1682/jrrd.2009.04.0047
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.