CoChat

At-home training with closed-loop augmented-reality cueing device for improving gait in patients with Parkinson disease

Espay, Alberto J., Baram, Yoram, Dwivedi, Alok Kumar, Shukla, Rakesh, Gartner, Maureen, Gaines, Laura, Duker, Andrew P., Revilla, Fredy J. · 2010 · The Journal of Rehabilitation Research and Development
Cited by 154

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Shuffling and freezing while walking can impair function in patients with Parkinson disease (PD). Open-loop devices that provide fixed-velocity visual or auditory cues can improve gait but may be unreliable or exacerbate freezing of gait in some patients. We examined the efficacy of a closed-loop, accelerometer-driven, wearable, visual-auditory cueing device in 13 patients with PD with off-state gait impairment at baseline and after 2 weeks of twice daily (30 minute duration) at-home use. We measured gait velocity, stride length, and cadence using a validated electronic gait-analysis system. Subjects underwent standard motor assessment and completed a self-administered Freezing of Gait Questionnaire (FOGQ) (range 0-24; lower is better). After training, device use enhanced walking velocity (61.6 ± 20.1 cm/s to 72.6 ± 26.5 cm/s, p = 0.006) and stride length (74.3 ± 16.4 cm to 84.0 ± 18.5 cm, p = 0.004). Upon device removal, walking velocity (64.5 ± 21.4 cm/s to 75.4 ± 21.5 cm/s, p < 0.001) and stride length (79.0 ± 20.3 cm to 88.8 ± 17.7 cm, p = 0.003) exhibited a greater magnitude of change, suggesting immediate residual benefits. Also upon device removal, nearly 70 percent of subjects improved by at least 20 percent in either walking velocity, stride length, or both. An overall improvement in gait was measured by the FOGQ (14.2 ±1.9 to 12.4 ± 2.5, p = 0.02). Although issues related to compliance and response variability render a definitive interpretation of study outcome difficult, devices using closed-loop sensory feedback appear to be effective and desirable nonpharmacologic interventions to improve walking in selected individuals with PD.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1682/jrrd.2009.10.0165

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 154

Metadata

Authors
Espay, A. J., Baram, Y., Dwivedi, A. K., Shukla, R., Gartner, M., Gaines, L., Duker, A. P., & Revilla, F. J.
Venue
The Journal of Rehabilitation Research and Development
Published
2010
Volume
47
Issue
6
Pages
573
ISSN
  • 0742-3241 (ISSN-L)
  • 0748-7711
OpenAlex
W2151033573
Cited by
154
References
2
FWCI
18.97
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: At-home training with closed-loop augmented-reality cueing device for improving gait in patients with Parkinson disease. https://app.cochat.ai/papers/10.1682/jrrd.2009.10.0165
The paper
Espay, A. J., Baram, Y., Dwivedi, A. K., Shukla, R., Gartner, M., Gaines, L., Duker, A. P., & Revilla, F. J. (2010). At-home training with closed-loop augmented-reality cueing device for improving gait in patients with Parkinson disease. The Journal of Rehabilitation Research and Development. https://doi.org/10.1682/jrrd.2009.10.0165

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.