Test No. 428: Skin Absorption: In Vitro Method
The DOI matches its Crossref record.
Abstract
This Test method has been designed to provide information on absorption of a test substance, (ideally radiolabelled), applied to the surface of a skin sample separating the two chambers (a donor chamber and a receptor chamber) of a diffusion cell. Static and flow-through diffusion cells are both acceptable. Skin from human or animal sources can be used. Although viable skin is preferred, non-viable skin can also be used. The skin has been shown to have the capability to metabolise some chemicals during percutaneous absorption. In this case, metabolites of the test chemical may be analysed by appropriate methods. Normally more than one concentration of the test substance is used in typical formulations, spanning the realistic range of potential human exposures. The application should mimic human exposure, normally 1-5 mg/cm2 of skin for a solid and up to 10 µl/cm2 for liquids. The temperature must be constant because it affects the passive diffusion of chemicals. The absorption of a test substance during a given time period (normally 24h) is measured by analysis of the receptor fluid and the distribution of the test substance chemical in the test system and the absorption profile with time should be presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
EFSA Scientific Committee, Hardy, A., Benford, D., Halldorsson, T., Jeger, M. J., Knutsen, H. K., More, S., Naegeli, H., Noteborn, H., Ockleford, C., et al. (2018) · EFSA Journal · doi:10.2903/j.efsa.2018.5327 · Cited by 416
Validation and quality control of replacement alternatives - current status and future challenges
Leist, M., Hasiwa, N., Daneshian, M., & Hartung, T. (2012) · Toxicology Research · doi:10.1039/c2tx20011b · Cited by 100
Skin models of cutaneous toxicity, transdermal transport and wound repair
Vilela de Sousa, I., Ferreira, M. J. S., Bebiano, L. B., Simões, S., Matos, A. F., Pereira, R. F., & Granja, P. L. (2023) · Burns & Trauma · doi:10.1093/burnst/tkad014 · Cited by 17
Metadata
- Authors
- OECD
- Venue
- OECD Guidelines for the Testing of Chemicals, Section 4
- Publisher
- OECD
- Published
- 2004-11-23
- ISSN
- 2074-5788 (ISSN-L)
- OpenAlex
- W4247390740
- Cited by
- 162
- References
- 0
- FWCI
- 0.39
- Type
- book
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Test No. 428: Skin Absorption: In Vitro Method. https://app.cochat.ai/papers/10.1787/9789264071087-en
- The paper
- OECD. (2004). Test No. 428: Skin Absorption: In Vitro Method. OECD Guidelines for the Testing of Chemicals, Section 4. https://doi.org/10.1787/9789264071087-en
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.