Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 163

The DOI matches its Crossref record.

Ammonia emission from dairy cow buildings: a review of measurement techniques, influencing factors and possibilities for reduction

Open access
Monteny, G.J., Erisman, J.W.·1998·Netherlands Journal of Agricultural Science

Abstract

This study aimed to make an analytical inventory of ammonia emission data of dairy housing systems and to assess possibilities for reduction, based upon the analysis of processes and factors involved in the production and volatilization of ammonia. Mass balance methods for the determination of air exchange rates for naturally ventilated dairy cow buildings that are based upon natural or introduced tracers may have good potential for application in emission studies. Differences occur in housing systems, floor types and manure collection and manure storage systems. Ammonia emission levels for cubicle (loose) houses are higher (20-45 g/day/cow) than for tie stalls (5-27 g/day/cow), and variation in emissions by housing type is large. Integration of knowledge of ammonia emission related processes and factors will support a more detailed analysis of differences and variation, and will allow optimization of possibilities for emission reduction. Substantial emission reductions of up to 50% for cubicle houses with slatted floors can be achieved through each of the following measures: flushing of floors with water or diluted formaldehyde, optimised feeding strategies, and slurry acidification. Highest reductions are possible through V-shaped, solid floors (52%) as a single measure, or in combination with flushing with water (65%) or diluted formaldehyde (80%). Providing that drawbacks are solved, nationwide introduction of one or more these measures will lead to a maximal reduction of the NH3 emission in the Netherlands to 18 kt per year.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.18174/njas.v46i3.481

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 163

Metadata

Authors
Monteny, G. J., & Erisman, J. W.
Venue
Netherlands Journal of Agricultural Science
Published
1998-12-01
Pages
225-247
ISSN
0028-2928 (ISSN-L)
OpenAlex
W2134476561
Cited by
163
References
0
FWCI
6.01
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Ammonia emission from dairy cow buildings: a review of measurement techniques, influencing factors and possibilities for reduction. https://app.cochat.ai/papers/10.18174/njas.v46i3.481
The paper
Monteny, G. J., & Erisman, J. W. (1998). Ammonia emission from dairy cow buildings: a review of measurement techniques, influencing factors and possibilities for reduction. Netherlands Journal of Agricultural Science. https://doi.org/10.18174/njas.v46i3.481

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.