The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
The Influence of Bone Thickness on Facial Marginal Bone Response: Stage 1 Placement Through Stage 2 Uncovering
Abstract
Background: Various causes of facial bone loss around dental implants are reported in the literature; however, reports on the influence of residual facial bone thickness on the facial bone response (loss or gain) have not been published. This study measured changes in vertical dimension of facial bone between implant insertion and uncovering and compared these changes to facial bone thickness for more than 3,000 hydroxyapatite (HA)‐coated and non–HA‐coated root‐form dental implants. Methods: Subjects were predominantly white males, 18 to 80+ years of age (mean 62.9 years), who were patients at 30 Department of Veterans Affairs Medical Centers and two university dental clinics. Alveolar ridges ranged from normal to resorbed with intact basal bone. Following preparation of the osteotomy site, direct measurements with calipers were made of the residual facial bone thickness, approximately 0.5 mm below the crest of the bone. The distance from the top of the implants to the crest of the facial bone was also measured using periodontal probes. Implants were uncovered between 3 to 4 months in the mandible and 6 to 8 months in the maxilla after insertion. Facial bone response was the difference between the height of facial bone at Stage 1 (insertion) and Stage 2 (uncovering). Results: The mean facial bone thickness after osteotomies were made was 1.7 ± 1.13 mm. When a mean facial bone thickness of 1.8 ± 1.41 mm or larger remained after site preparation, bone apposition was more likely to occur. The mean facial bone response for 2,685 implants was −0.7 ± 1.70 mm. For implants integrated at uncovering, the mean bone response was −0.7 ± 1.69 mm, and −2.8 ± 1.57 mm for implants mobile at uncovering. Bone quality‐4 had the least facial bone response, −0.5 ± 2.11 mm. Bone responses were similar for both HA‐coated and non—HA‐coated implants. Conclusions: Significantly greater amounts of facial bone loss were associated with implants that failed to integrate. As the bone thickness approached 1.8 to 2 mm, bone loss decreased significantly and some evidence of bone gain was seen. There was no statistically or clinically significant difference in bone response between HA‐coated and non—HA‐coated implants. Ann Periodontol 2000;5:119‐128.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tissue-Integrated Prostheses. Osseointegration in Clinical Dentistry
Brånemark, P., Zarb, G. A., Albrektsson, T. O., & Rosen, H. M. (1986) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-198603000-00037 · Cited by 1,556
The Excessive Loss of Branemark Fixtures in Type IV Bone: A 5‐Year Analysis
Jaffin, R. A., & Berman, C. L. (1991) · Journal of Periodontology · doi:10.1902/jop.1991.62.1.2 · Cited by 1,049
The topography of the vascular systems in the periodontal and peri‐implant tissues in the dog
Berglundh, T., Lindhe, J., Jonsson, K., & Ericsson, I. (1994) · Journal of Clinical Periodontology · doi:10.1111/j.1600-051x.1994.tb00302.x · Cited by 319
Mechanical Loading of Branemark Implants Affects Interfacial Bone Modeling and Remodeling
Hoshaw, S. J. (1994) · The International Journal of Oral & Maxillofacial Implants · Cited by 292
Distribution of Bone Quality in Patients Receiving Endosseous Dental Implants
Truhlar, R. S., Orenstein, I. H., Morris, H. F., & Ochi, S. (1997) · Journal of Oral and Maxillofacial Surgery · doi:10.1016/s0278-2391(16)31196-x · Cited by 196
Self-citationThe Influence of Bone Quality on Periotest Values of Endosseous Dental Implants at Stage II Surgery
Truhlar, R. S., Lauciello, F. R., Morris, H. F., & Ochi, S. (1997) · Journal of Oral and Maxillofacial Surgery · doi:10.1016/s0278-2391(16)31198-3 · Cited by 44
Self-citation
Cited by
Tavelli, L., Barootchi, S., Avila‐Ortiz, G., Urban, I. A., Giannobile, W. V., & Wang, H. (2021) · Journal of Periodontology · doi:10.1002/jper.19-0716 · Cited by 336
Avila‐Ortiz, G., Gonzalez‐Martin, O., Couso‐Queiruga, E., & Wang, H. (2020) · Journal of Periodontology · doi:10.1002/jper.19-0566 · Cited by 268
The biological width around implant
Zheng, Z., Ao, X., Xie, P., Jiang, F., & Chen, W. (2021) · Journal of Prosthodontic Research · doi:10.2186/jpr.jpor_2019_356 · Cited by 84
Metadata
- Authors
- Spray, J. R., Black, C. G., Morris, H. F., & Ochi, S.
- Venue
- Annals of Periodontology
- Publisher
- Wiley
- Published
- 2000-12
- Volume
- 5
- Issue
- 1
- Pages
- 119-128
- ISSN
- 1553-0841 (ISSN-L)
- 2162-5131
- OpenAlex
- W2176903192
- Cited by
- 547
- References
- 6
- FWCI
- 4.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.