Fluids and Microbial Penetration in the Internal Part of Cement‐Retained Versus Screw‐Retained Implant‐Abutment Connections
The DOI matches its Crossref record.
Abstract
Background: It has been recently observed that in implants with screwretained abutments, in in vitro as well as in vivo conditions, bacteria can penetrate inside the internal cavity of the implant as a consequence of leakage at the implant‐abutment interface. An alternative to screw‐retained abutments is represented by implants that can receive cemented abutments. In this case, the abutment goes through a transmucosal friction implant extension (collar) and is cemented inside the internal hexagonal portion of the implant. The aim of the present research was to compare fluids and bacterial penetration in 2 different implant systems, one with cement‐retained abutments (CRA) and the other with screw‐retained abutments (SRA). Methods: Twelve CRA dental implants and 12 SRA implants were used in this study. The research was done in 3 steps: scanning electron microscopic (SEM) analysis, fluid penetration analysis, and bacterial penetration analysis. Results: 1) Under SEM it was possible to observe in the SRA implants a mean 2 to 7 μ gap between implant and abutment, while in the CRA implants, the gap was 7 μ. In the latter group, however, the gap was always completely filled by the fixation cement. All the spaces between abutment and implant were filled by the cement. 2) With SRA implants, it was possible to observe the presence of toluidine blue at the level of the fixtureabutment interface and the internal threads; the absorbent paper was stained in all cases. With CRA implants, the absorbent paper inside the hollow portion of the implants was never stained by toluidine blue. No penetration of toluidine blue was observed at the implant‐abutment interface and inside the hollow portion of the implants. 3) In all the SRA implant assemblies, bacterial penetration was observed at the implant‐abutment interface. No bacteria were detected in the hollow portion of the CRA implants. Conclusion: On the basis of the results obtained in the present study using 2 different implant systems, we conclude that CRA implants offer better results relating to fluid and bacterial permeability compared to SRA implants. J Periodontol 2001;72:1146‐1150.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Peri-implant Inflammation Defined by the Implant-Abutment Interface
Broggini, N., McManus, L. M., Hermann, J. S., Medina, R., Schenk, R. K., Buser, D., & Cochran, D. L. (2006) · Journal of Dental Research · doi:10.1177/154405910608500515 · Cited by 480
Biofilm and dental implant: The microbial link
Dhir, S. (2013) · Journal of Indian Society of Periodontology · doi:10.4103/0972-124x.107466 · Cited by 129
“Piatelli et al. , [32] In vitro Cement retained abutments exhibit decreased bacterial permeability as compared to screw retained ‑ Teixeira et al. , [33] In vitro Microbial penetration of the S. aureus in both the morse taper and internal hexagon implant abutment connection”
Metadata
- Authors
- Piattelli, A., Scarano, A., Paolantonio, M., Assenza, B., Leghissa, G. C., Di Bonaventura, G., Catamo, G., & Piccolomini, R.
- Venue
- Journal of Periodontology
- Publisher
- Wiley
- Published
- 2001-09
- Volume
- 72
- Issue
- 9
- Pages
- 1146-1150
- ISSN
- 0022-3492 (ISSN-L)
- 1943-3670
- OpenAlex
- W2042823684
- Cited by
- 158
- References
- 0
- FWCI
- 3.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.