Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 635

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Dimensions of Peri‐Implant Mucosa: An Evaluation of Maxillary Anterior Single Implants in Humans

Kan, Joseph Y.K., Rungcharassaeng, Kitichai, Umezu, Kiyotaka, Kois, John C.·2003·Journal of Periodontology

Abstract

Background: Attempts have been made to evaluate the biologic dimension of osseointegrated implants; however, most are histologic studies in animals, and the effect of soft tissue support from adjacent teeth on the interproximal dimension of the peri‐implant mucosa for anterior single implants has not been addressed. This study clinically evaluated the dimensions of the periimplant mucosa around 2‐stage maxillary anterior single implants in humans after 1 year of function. The influence of the peri‐implant biotype was also examined Methods: Forty‐five patients (20 males and 25 females) with a mean age of 47.3 years were included in this study. A total of 45 maxillary anterior single implant crowns with a mean functional time of 32.5 months (range, 12 to 78) were evaluated. The dimensions of peri‐implant mucosa were measured by bone sounding using a periodontal probe at the mesial (MI), mid‐facial (F), and distal (DI) aspects of the implant restoration and the proximal aspects (MT, DT) of adjacent natural teeth. In addition, the peri‐implant biotype was evaluated and categorized as thick or thin. Statistical analysis was performed using an independent t test (P <0.05). Results: The means and standard deviations of the dimensions of peri‐implant mucosa at MT, MI, F, DI, and DT were 4.20 ± 0.77 mm, 6.17 ± 1.27 mm, 3.63 ± 0.91 mm, 5.93 ± 1.21 mm, and 4.20 ± 0.64 mm, respectively. The dimensions of peri‐implant mucosa in the thick biotype were significantly greater than the thin biotype at MT, MI, and DT (P<0.05). Conclusions: The mean facial dimension of periimplant mucosa of 2‐stage implants is slightly greater than the average dimension of the dentogingival complex. The level of the interproximal papilla of the implant is independent of the proximal bone level next to the implant, but is related to the interproximal bone level next to the adjacent teeth. Greater periimplant mucosal dimensions were noted in the presence of a thick peri‐implant biotype as compared to a thin biotype.J Periodontol 2003;74:557‐562.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1902/jop.2003.74.4.557

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 635

Metadata

Authors
Kan, J. Y. K., Rungcharassaeng, K., Umezu, K., & Kois, J. C.
Venue
Journal of Periodontology
Publisher
Wiley
Published
2003-04
Volume
74
Issue
4
Pages
557-562
ISSN
  • 0022-3492 (ISSN-L)
  • 1943-3670
OpenAlex
W2167075089
Cited by
635
References
1
FWCI
9.31
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Dimensions of Peri‐Implant Mucosa: An Evaluation of Maxillary Anterior Single Implants in Humans. https://app.cochat.ai/papers/10.1902/jop.2003.74.4.557
The paper
Kan, J. Y. K., Rungcharassaeng, K., Umezu, K., & Kois, J. C. (2003). Dimensions of Peri‐Implant Mucosa: An Evaluation of Maxillary Anterior Single Implants in Humans. Journal of Periodontology. https://doi.org/10.1902/jop.2003.74.4.557

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.