The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Accuracy of Two Stereolithographic Guide Systems for Computer‐Aided Implant Placement: A Computed Tomography‐Based Clinical Comparative Study
Abstract
Background: Stereolithographic surgical guides provide significant benefits during the simultaneous placement of multiple implants with regard to the final prosthetic plan. However, deviation from the planning poses a significant risk. Deviations of implants that were placed by bone‐, tooth‐, and mucosa‐supported stereolithographic surgical guides were examined in this study. Methods: After enrolling 54 eligible patients, 294 implants were planned on cone‐beam computerized tomography CB(CT)‐derived images. Sixty guides, both single‐ and multiple‐type, were produced using two commercial systems. Mucosa‐supported guides were fixed with osteosynthesis screws. Implants were inserted, and at the end of osseointegration period, a new CB(CT) scan was performed. Preoperative planning was merged with the new CB(CT) data to identify the deviations between the planned and placed implants for each support type and manufacturer. The Kruskal‐Wallis and Mann‐Whitney U tests were used for comparison (P <0.05). Results: There were no damage‐related complications in any critical anatomy. Implants that were placed by bone‐supported guides had the highest mean deviations (5.0° ± 1.66° angular, and 1.70 ± 0.52 mm and 1.99 ± 0.64 mm for implant shoulder and tip, respectively), whereas the lowest deviations were measured in implants that were placed by mucosa‐supported guides (2.9° ± 0.39° angular, and 0.7 ± 0.13 mm and 0.76 ± 0.15 mm for implant shoulder and tip, respectively). Conclusions: Computer‐aided planning and manufacturing surgical guides in accordance with CB(CT) images may help clinicians place implants. Rigid screw fixation of a single guide incorporating metal sleeves and a special drill kit further minimizes deviations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multimodality image registration by maximization of mutual information
Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., & Suetens, P. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563664 · Cited by 4,547
Cited by
Computer Technology Applications in Surgical Implant Dentistry: A Systematic Review
Tahmaseb, A., Wismeijer, D., Coucke, W., & Derksen, W. (2014) · The International Journal of Oral & Maxillofacial Implants · doi:10.11607/jomi.2014suppl.g1.2 · Cited by 791
Current and emerging applications of 3D printing in medicine
Liaw, C.-Y., & Guvendiren, M. (2017) · Biofabrication · doi:10.1088/1758-5090/aa7279 · Cited by 604
Accuracy of medical models made by additive manufacturing (rapid manufacturing)
Salmi, M., Paloheimo, K.-S., Tuomi, J., Wolff, J., & Mäkitie, A. (2013) · Journal of Cranio-Maxillofacial Surgery · doi:10.1016/j.jcms.2012.11.041 · Cited by 330
Accuracy of computer‐aided implant placement
Van Assche, N., Vercruyssen, M., Coucke, W., Teughels, W., Jacobs, R., & Quirynen, M. (2012) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2012.02552.x · Cited by 328
Raico Gallardo, Y. N., da Silva‐Olivio, I. R. T., Mukai, E., Morimoto, S., Sesma, N., & Cordaro, L. (2017) · Clinical Oral Implants Research · doi:10.1111/clr.12841 · Cited by 259
Metadata
- Authors
- Arısan, V., Karabuda, Z. C., & Özdemir, T.
- Venue
- Journal of Periodontology
- Publisher
- Wiley
- Published
- 2010-01
- Volume
- 81
- Issue
- 1
- Pages
- 43-51
- ISSN
- 0022-3492 (ISSN-L)
- 1943-3670
- OpenAlex
- W2121345515
- Cited by
- 210
- References
- 1
- FWCI
- 14.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Accuracy of Two Stereolithographic Guide Systems for Computer‐Aided Implant Placement: A Computed Tomography‐Based Clinical Comparative Study. https://app.cochat.ai/papers/10.1902/jop.2009.090348
- The paper
- Arısan, V., Karabuda, Z. C., & Özdemir, T. (2010). Accuracy of Two Stereolithographic Guide Systems for Computer‐Aided Implant Placement: A Computed Tomography‐Based Clinical Comparative Study. Journal of Periodontology. https://doi.org/10.1902/jop.2009.090348
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.