The DOI matches its Crossref record; the references it cites are not checked yet.
THE EFFECT OF DELAY IN TEMPERATURE VARIATIONS ON RESULTS OF GLUCOSE TEST IN DM PATIENTS WITH HYPERCHOLESTEROLEMIA
Abstract
Background: The pre-analytic stage has the most significant contribution to error, which is 60% to 70%. This is an excellent contribution to the dependability of laboratory results. Delays in the examination often occur in the laboratory due to various factors influencing glucose examination outcomes. Purpose: To ascertain the effect of long delays in various temperatures on the results of plasma NaF and serum glucose tests in diabetes mellitus patients who have hypercholesterolemia. Method: Pre-test and post-test design used in a pre-experimental method. In the pretest, plasma NaF and serum glucose levels were checked immediately. In the posttest, the plasma NaF and serum samples were delayed for 4 and 8 hours at the temperature of the refrigerator (4°C) and room temperature (25°C). Result: The results of One-way ANOVA test analysis of the plasma NaF glucose level with an immediate examination, a delay of 4 and 8 hours at room temperature (25°C) showed no effect with a Sig. of 0.423 > 0.05. Plasma NaF glucose level with an immediate examination, 4 and 8 hours delay in refrigerator temperature (4°C) showed no effect with Sig. of 0.772 > 0.05. Serum glucose levels with an immediate examination, 4 and 8 hours delay at room temperature (25°C) showed no effect with a Sig. of 0.333 > 0.05. Serum glucose levels with an immediate examination, 4 and 8 hours delay in refrigerator temperature (4°C) showed no effect with a Sig. of 0.604 > 0.05. Conclusion: There was no effect of 4 hours and 8 hours of delay at the temperature of the refrigerator (4°C) and room temperature (25°C) on the results of NaF and serum glucose examinations in patients with diabetes mellitus who have hypercholesterolemia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
The citation lists haven’t been fetched yet
Research works printed but not linked: 15
- Agung, A., Retnoningrum, D., KSL, I.E., 2017. Perbedaan Kadar Glukosa Serum dan Plasma Natrium Fluorida (Naf) dengan Penundaan Pemeriksaan. J. Kedokt. Diponegoro Vol. 6(2), Pp. 188-195.
- Apriani, A., Umami, A., 2018. Perbedaan Kadar Glukosa Darah pada Plasma EDTA dan Serum dengan Penundaan Pemeriksaan. J. Vokasi Kesehat. Vol. 4(1), Pp. 19-22. · DOI
- Fahmi, N.F., Firdaus, N., Putri, N., 2020. Pengaruh Waktu Penundaan terhadap Kadar Glukosa Darah Sewaktu dengan Metode Poct pada Mahasiswa. Nurs. Updat. J.Ilm. Ilmu Keperawatan Vol. 11(2), Pp. 1-11.
- Kasimo, E.R., 2020. Perbedaan Glukosa Serum dan Plasma NaF dengan Penundaan 12 Jam pada Pasien Diabetes Melitus. J. Kedokt. dan Kesehat. Vol. 16(1), Pp. 20-24. · DOI
- Moe, M.O., Okstad, W., Berland, S., Berland, S.B., 2018. Effects of Storage Duration and Temperature Conditions on Biochemical Analytes in Porcine Clotted. J. Dairy, Vet. Anim. Res. Vol. 7(1), Pp. 1-6. · DOI
- Noviyanti, F., Decroli, E., Sastri, S., 2015. Perbedaan Kadar LDL-kolesterol pada Pasien Diabetes Melitus Tipe 2 dengan dan tanpa Hipertensi di RS Dr . M .Djamil Padang Tahun 2011. J. Kesehat. Andalas Vol. 4(2), Pp. 20-24. · DOI
- Nurhayati, E., Suwono, S., Fiki, E.N., 2017. Penggunaan Antikoagulan Naf pada Pengukuran Kadar Glukosa Darah Selama 2 Jam. J. Lab. Khatulistiwa Vol. 1(1), Pp. 33-39. · DOI
- Putra, A.L., Wowor, P.M., Wungouw, H.I.S., 2015. Gambaran Kadar Gula Darah Sewaktu Pada Mahasiswa Angkatan 2015 Fakultas Kedokteran Universitas Sam Ratulangi Manado. J. e-Biomedik 3. · DOI
- Ramadhani, Q.A.N., Garini, A., Nurhayati, Harianja, S.H., 2019. Perbedaan Kadar Glukosa Darah Sewaktu menggunakan Serum dan Plasma Edta. J. Kesehat. Poltekkes Palembang Vol. 14(2), Pp. 80-84. · DOI
- Santi, O.D., Rosita, L., Cahyaningrum, Y.D., 2011. Pengaruh Suhu dan Interval Waktu Penyimpanan Sampel Serum pada Pengukuran Kadar Glukosa Darah. JKKI (Jurnal Kedokt. dan Kesehat. Indones. Vol. 3(8), Pp. 39-43.
- Sasmita, B., Yaswir, R., Lillah, H., Desywar, D., 2020. Perubahan Kadar Glukosa Plasma Naf dan Serum yang Disimpan Antara Suhu Ruangan dan Suhu 2-8ËšC. Program Pendidikan Dokter Spesialis IBagian Patologi Klikik FK UNAND/RSUP. DR. M.DJAMIL Padang. · DOI
- Stoll, C., Wolkers, W.F., 2011. Membrane Stability during Biopreservation of Blood Cells. Transfus. Med. Hemotherapy J. Vol. 38(2), Pp. 89-97. · DOI
- Sujono, S., Maulida, Y.A., Sari, M.P., 2016. Kadar Protein Total dan Ureum dengan dan tanpa Penambahan γ-cyclodextrin pada Serum Lipemik. Clin. Chem. Vol. 5(1), Pp. 16-19.
- Susiwati, S., 2018. Perbedaan Kadar Glukosa Darah Puasa Pasien Diabetes Melitus Tipe 2 pada Plasma Naf Berdasarkan Waktu Pemeriksaan di Rsud Dr. M.Yunus Provinsi Bengkulu Tahun 2017. J. Nurs.Public Heal. Vol. 6(1), Pp. 82-87. · DOI
- Trisyani, N., Djasang, S., Armah, Z., 2020. Perbandingan Kadar Glukosa Darah Pada Sampel Yang Mengalami Variasi Lama Penundaan Pemisahan. J. Media Anal. Kesehat. 11, 34. · DOI
Metadata
- Authors
- Khotul Ula, C., Edy Haryanto, E. H., Syamsul Arifin, S. A., & Istanto, W.
- Venue
- Journal of Vocational Health Studies
- Publisher
- Universitas Airlangga
- Published
- 2023-07-30
- Volume
- 7
- Issue
- 1
- Pages
- 10-16
- ISSN
- 2580-717X
- 2580-7161
- Cited by
- 0
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: THE EFFECT OF DELAY IN TEMPERATURE VARIATIONS ON RESULTS OF GLUCOSE TEST IN DM PATIENTS WITH HYPERCHOLESTEROLEMIA. https://app.cochat.ai/papers/10.20473/jvhs.v7.i1.2023.10-16
- The paper
- Khotul Ula, C., Edy Haryanto, E. H., Syamsul Arifin, S. A., & Istanto, W. (2023). THE EFFECT OF DELAY IN TEMPERATURE VARIATIONS ON RESULTS OF GLUCOSE TEST IN DM PATIENTS WITH HYPERCHOLESTEROLEMIA. Journal of Vocational Health Studies. https://doi.org/10.20473/jvhs.v7.i1.2023.10-16
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.