Impact of image preprocessing on the volume dependence and prognostic potential of radiomics features in non-small cell lung cancer
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Background: Radiomics features have been used in a variety of studies to predict patient outcomes or aid in the diagnosis of non-small cell lung cancer. However, no guidelines exist for the best way to calculate these features to maximize their prognostic potential. The purpose of the current study was to evaluate how different image pre-processing techniques may impact both the volume dependence and prognostic potential of the features in univariate analyses.Methods: Radiomics features from the histogram, co-occurrence matrix, neighborhood gray-tone difference matrix and run-length matrix were calculated from a set of computed tomography (CT) images of 107 non-small cell lung cancer tumors with volumes ranging from 5 to 567 cm3. Features were calculated from the images with no pre-processing, 8 bit depth resampling, Butterworth smoothing, or both 8 bit depth resampling and Butterworth smoothing. To determine which features were correlated with volume, we calculated the Spearman rank correlation coefficient (rs) for each feature and preprocessing combination. For features that had very high volume correlations (rs >0.95) regardless of which preprocessing algorithm was used, we normalized the algorithm for volume and recalculated the volume correlation. To determine whether the preprocessing technique affected the usefulness of the feature, we fitted univariate Cox proportional hazards models for all four preprocessing techniques for each feature and calculated the P value. Additionally, univariate cox models were recalculated using leave-one-out cross validation to generate risk predictions for each patient. As a result, each patient had a predicted outcome for each model in which the patient was not involved in the model building. The prediction accuracy was assessed using Harrell’s concordance index (c-index). Finally, the ability of each feature to improve model fit was examined using the P value of the log-likelihood ratio between a model built using volume only and a model built using volume and one radiomics feature. The Benjamini-Hochberg procedure was used for multiplicity correction.Results: Five features were entirely volume dependent (busyness, coarseness, grey-level non-uniformity, run-length non-uniformity, and energy) and new algorithms were proposed for these features. Both the correlation with volume and the prognostic value of individual features changed substantially with different preprocessing techniques. In general, preprocessed features that were at least slightly correlated with volume (rs >0.5) were more likely to be significant in the univariate analysis. Additionally, Butterworth smoothing, used either alone or in conjunction with 8 bit depth resampling, most often yielded features that were significant in univariate analysis.Conclusions: Preprocessing can have a strong impact on the volume dependence of a feature, and its significance in univariate models. To create standardized features useful for multivariate modeling, it will be important to balance the usefulness of features with their volume dependence.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Decoding tumour phenotype by noninvasive imaging using a quantitative radiomics approach
Aerts, H. J. W. L., Velazquez, E. R., Leijenaar, R. T. H., Parmar, C., Grossmann, P., Carvalho, S., Bussink, J., Monshouwer, R., Haibe-Kains, B., Rietveld, D., et al. (2014) · Nature Communications · doi:10.1038/ncomms5006 · Cited by 5,132 · cited 3×
“Features extracted from computed tomography (CT) images have been claimed to be correlated with overall survival (1,2,4,5), gene expression patterns (1,4,6), pathologic findings (7), and stage (3).”
Background
Cited by
Repeatability and Reproducibility of Radiomic Features: A Systematic Review
Traverso, A., Wee, L., Dekker, A., & Gillies, R. (2018) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2018.05.053 · Cited by 903
Intrinsic dependencies of CT radiomic features on voxel size and number of gray levels
Shafiq‐ul‐Hassan, M., Zhang, G. G., Latifi, K., Ullah, G., Hunt, D. C., Balagurunathan, Y., Abdalah, M. A., Schabath, M. B., Goldgof, D. G., Mackin, D., et al. (2017) · Medical Physics · doi:10.1002/mp.12123 · Cited by 585
Self-citationScapicchio, C., Gabelloni, M., Barucci, A., Cioni, D., Saba, L., & Neri, E. (2021) · La radiologia medica · doi:10.1007/s11547-021-01389-x · Cited by 435
Delta-radiomics features for the prediction of patient outcomes in non–small cell lung cancer
Fave, X., Zhang, L., Yang, J., Mackin, D., Balter, P., Gomez, D., Followill, D., Jones, A. K., Stingo, F., Liao, Z., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-00665-z · Cited by 353
Self-citationVulnerabilities of radiomic signature development: The need for safeguards
Welch, M. L., McIntosh, C., Haibe-Kains, B., Milosevic, M. F., Wee, L., Dekker, A., Huang, S. H., Purdie, T. G., O'Sullivan, B., Aerts, H. J. W. L., et al. (2019) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2018.10.027 · Cited by 320
Metadata
- Authors
- Fave, X., Zhang, L., Yang, J., Mackin, D., Balter, P., Gomez, D., Followill, D., Jones, A. K., Stingo, F., & Court, L. E.
- Venue
- Translational Cancer Research
- Publisher
- AME Publishing Company
- Published
- 2016-08
- Volume
- 5
- Issue
- 4
- Pages
- 349-363
- ISSN
- 2218-676X (ISSN-L)
- 2219-6803
- OpenAlex
- W2510617171
- Cited by
- 120
- References
- 1
- FWCI
- 9.99
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.