The DOI matches its Crossref record.
Loads on the lumbar spine. Validation of a biomechanical analysis by measurements of intradiscal pressures and myoelectric signals.
Abstract
UNLABELLED: We studied the validity of predictions of compressive loads on the lumbar spine and contraction forces in lumbar trunk muscles based on a biomechanical model. The predictions were validated by quantitative measurements of myoelectric activities at twelve locations on the trunk and of the pressure in the third lumbar disc. Twenty-five tasks were performed isometrically by four healthy volunteers. The model predicted that the tasks imposed mean compressive loads on the spine of as much as 2400 newtons and required contraction forces of the posterior muscles of the back of as much as 1800 newtons. Intradiscal pressures of as much as 1600 kilopascals were measured. The predicted and measured quantities were well correlated. It appears that the model adequately predicted the compressive loads on the lumbar spine and the tensions in the back muscles. CLINICAL RELEVANCE: Patients with low-back disorders limit their physical activities, which indicates that loading on the spine must be a factor in those disorders. This study shows that the loads imposed on the spine by physical activities need not be measured. They can easily be calculated. This will significantly accelerate biomechanics research on low-back disorders. The calculation techniques that we validated for predicting loads on the spine can be used to calculate the loads on any skeletal structure. Those loads are largely determined not by the externally applied loads, but by the moments of those applied loads and by the moments of the weights of the body segments that the structure must support.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Revised NIOSH equation for the design and evaluation of manual lifting tasks
WATERS, T. R., PUTZ-ANDERSON, V., GARG, A., & FINE, L. J. (1993) · Ergonomics · doi:10.1080/00140139308967940 · Cited by 2,042
New In Vivo Measurements of Pressures in the Intervertebral Disc in Daily Life
Wilke, H., Neef, P., Caimi, M., Hoogland, T., & Claes, L. E. (1999) · Spine · doi:10.1097/00007632-199904150-00005 · Cited by 1,498
New approaches for interpreting projected bone densitometry data
Professor Carter, D. R., Bouxsein, M. L., & Marcus, R. (1992) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650070204 · Cited by 1,065
Biomechanical risk factors for occupationally related low back disorders
MARRAS, W. S., LAVENDER, S. A., LEURGANS, S. E., FATHALLAH, F. A., FERGUSON, S. A., GARY ALLREAD, W., & RAJULU, S. L. (1995) · Ergonomics · doi:10.1080/00140139508925111 · Cited by 585
Biomaterials for intervertebral disc regeneration and repair
Bowles, R. D., & Setton, L. A. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.03.013 · Cited by 344
Metadata
- Authors
- Schultz, A., Andersson, G., Ortengren, R., Haderspeck, K., & Nachemson, A.
- Venue
- The Journal of Bone & Joint Surgery
- Published
- 1982-06
- Volume
- 64
- Issue
- 5
- Pages
- 713-720
- ISSN
- 0021-9355 (ISSN-L)
- OpenAlex
- W2283868563
- Cited by
- 453
- References
- 0
- FWCI
- 6.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Loads on the lumbar spine. Validation of a biomechanical analysis by measurements of intradiscal pressures and myoelectric signals. https://app.cochat.ai/papers/10.2106/00004623-198264050-00008
- The paper
- Schultz, A., Andersson, G., Ortengren, R., Haderspeck, K., & Nachemson, A. (1982). Loads on the lumbar spine. Validation of a biomechanical analysis by measurements of intradiscal pressures and myoelectric signals. The Journal of Bone & Joint Surgery. https://doi.org/10.2106/00004623-198264050-00008
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.