The DOI matches its Crossref record.
Patellofemoral contact pressures. The influence of q-angle and tendofemoral contact.
Abstract
Controlled bending moments were applied to twelve human cadaver knee joints using a special loading fixture that allowed variation of both the Q-angle and the flexion angle. The joints were tested at three different Q-angles (physiological, increased 10 degrees, and decreased 10 degrees) and five different angles of flexion (ranging from 20 to 120 degrees). Based on one-third of values in the literature for maximum voluntary isometric quadriceps moments, we applied resultant knee moments of 23.6, 30.7, 47.2, and 35.0 newton-meters at 20, 30, 60, and 90 degrees of flexion, respectively. Based on two-thirds of reported maximum moments, we applied 47.2 newton-meters at 120 degrees of flexion. Normal patellofemoral-contact pressures, measured with a pressure-sensitive film, were remarkably uniformly distributed (+/- 0.25 megapascal ), with approximately the same pressure on the lateral and medial patellar facets. The maximum contact force occurred at 90 degrees of flexion. Extrapolating our measurements to full in vivo moments, we estimated maximum contact forces of 4600 newtons , or approximately 6.5 times body weight. Tendofemoral contact at 120 degrees of knee flexion supported one-third of the total contact force on the patella. A 10-degree increase in the Q-angle resulted in increased peak pressures (an increase of 45 per cent at 20 degrees of flexion). A decrease in the Q-angle resulted in unloading of the vertical crest and, in some knees, of parts of the lateral facet. However, these decreases were always associated with increased peak pressures (50 per cent more at 20 degrees of flexion) at other locations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Epidemiology and Natural History of Acute Patellar Dislocation
Fithian, D. C., Paxton, E. W., Stone, M. L., Silva, P., Davis, D. K., Elias, D. A., & White, L. M. (2004) · The American Journal of Sports Medicine · doi:10.1177/0363546503260788 · Cited by 1,202
Knee biomechanics of the dynamic squat exercise
ESCAMILLA, R. F. (2001) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200101000-00020 · Cited by 570
Willson, J. D., & Davis, I. S. (2008) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2007.08.025 · Cited by 386
The Influence of Tibial and Femoral Rotation on Patellofemoral Contact Area and Pressure
Lee, T. Q., Morris, G., & Csintalan, R. P. (2003) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.2003.33.11.686 · Cited by 375
Effects of technique variations on knee biomechanics during the squat and leg press
ESCAMILLA, R. F., FLEISIG, G. S., ZHENG, N., LANDER, J. E., BARRENTINE, S. W., ANDREWS, J. R., BERGEMANN, B. W., & MOORMAN, C. T. (2001) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200109000-00020 · Cited by 372
Metadata
- Authors
- Huberti, H. H., & Hayes, W. C.
- Venue
- The Journal of Bone & Joint Surgery
- Published
- 1984-06
- Volume
- 66
- Issue
- 5
- Pages
- 715-724
- ISSN
- 0021-9355 (ISSN-L)
- OpenAlex
- W2098954998
- Cited by
- 840
- References
- 0
- FWCI
- 8.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Patellofemoral contact pressures. The influence of q-angle and tendofemoral contact. https://app.cochat.ai/papers/10.2106/00004623-198466050-00010
- The paper
- Huberti, H. H., & Hayes, W. C. (1984). Patellofemoral contact pressures. The influence of q-angle and tendofemoral contact. The Journal of Bone & Joint Surgery. https://doi.org/10.2106/00004623-198466050-00010
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.