The DOI matches its Crossref record.
Comparison of indium-labeled-leukocyte imaging with sequential technetium-gallium scanning in the diagnosis of low-grade musculoskeletal sepsis. A prospective study.
Abstract
We prospectively compared sequential technetium-gallium imaging with indium-labeled-leukocyte imaging in fifty patients with suspected low-grade musculoskeletal sepsis. Adequate images and follow-up examinations were obtained for forty-two patients. The presence or absence of low-grade sepsis was confirmed by histological and bacteriological examinations of tissue specimens taken at surgery in thirty of the forty-two patients. In these thirty patients, the sensitivity of sequential Tc-Ga imaging was 48 per cent, the specificity was 86 per cent, and the accuracy was 57 per cent, whereas the sensitivity of the indium-labeled-leukocyte technique was 83 per cent, the specificity was 86 per cent, and the accuracy was 83 per cent. When the additional twelve patients for whom surgery was deemed unnecessary were considered, the sensitivity of sequential Tc-Ga imaging was 50 per cent, the specificity was 78 per cent, and the accuracy was 62 per cent, as compared with a sensitivity of 83 per cent, a specificity of 94 per cent, and an accuracy of 88 per cent with the indium-labeled-leukocyte method. In patients with a prosthesis the indium-labeled-leukocyte image was 94 per cent accurate, compared with 75 per cent accuracy for sequential Tc-Ga imaging. Statistical analysis of these data demonstrated that the indium-labeled-leukocyte technique was superior to sequential Tc-Ga imaging in detecting areas of low-grade musculoskeletal sepsis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Zhuang, H., & Alavi, A. (2002) · Seminars in Nuclear Medicine · doi:10.1053/snuc.2002.29278 · Cited by 524
Infection after total hip arthroplasty. Past, present, and future.
Garvin, K. L., & Hanssen, A. D. (1995) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199510000-00015 · Cited by 497
New Developments in Diagnosis and Treatment of Infection in Orthopedic Implants
Widmer, A. F. (2001) · Clinical Infectious Diseases · doi:10.1086/321863 · Cited by 407
The role of intraoperative frozen sections in revision total joint arthroplasty.
Feldman, D. S., Lonner, J. H., Desai, P., & Zuckerman, J. D. (1995) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199512000-00003 · Cited by 296
LONNER, J. H., DESAI, P., DICESARE, P. E., STEINER, G., & ZUCKERMAN, J. D. (1996) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199610000-00014 · Cited by 286
Metadata
- Authors
- Merkel, K. D., Brown, M. L., Dewanjee, M. K., & Fitzgerald, R. H.
- Venue
- The Journal of Bone & Joint Surgery
- Published
- 1985-03
- Volume
- 67
- Issue
- 3
- Pages
- 465-476
- ISSN
- 0021-9355 (ISSN-L)
- OpenAlex
- W1954685123
- Cited by
- 167
- References
- 0
- FWCI
- 7.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of indium-labeled-leukocyte imaging with sequential technetium-gallium scanning in the diagnosis of low-grade musculoskeletal sepsis. A prospective study. https://app.cochat.ai/papers/10.2106/00004623-198567030-00018
- The paper
- Merkel, K. D., Brown, M. L., Dewanjee, M. K., & Fitzgerald, R. H. (1985). Comparison of indium-labeled-leukocyte imaging with sequential technetium-gallium scanning in the diagnosis of low-grade musculoskeletal sepsis. A prospective study. The Journal of Bone & Joint Surgery. https://doi.org/10.2106/00004623-198567030-00018
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.