The DOI matches its Crossref record.
Closed locked intramedullary nailing. Its application to comminuted fractures of the femur.
Abstract
For many fractures of the femoral shaft, closed intramedullary nailing will not control rotation or telescoping of the fragments. Locked intramedullary nailing combines closed nailing with the percutaneous insertion of screws that interlock the bone and nail. This method permits static locking that controls rotation and telescoping and subsequently conversion to dynamic locking when weight-bearing is started after approximately twelve weeks. By providing greater stability, this method extends the indications for intramedullary nailing to severely comminuted, oblique, and spiral fractures as well as to fractures complicated by loss of bone and fractures in the proximal and distal ends of the femoral shaft. Of fifty-two patients with forty-nine severely comminuted fractures of the femoral shaft and three fractures that were complicated by loss of bone, forty-seven patients had uneventful consolidation of the fracture, with a mean time of 4.5 months for the severely comminuted fractures and seven months for the fractures that had a loss of bone. At follow-up, all forty-seven patients had normal motion of the hip, and forty-five had normal motion of the knee. Of the remaining five patients, four had a non-union that eventually healed (three after a second locked nailing and one after a third) and one had a septic non-union that eventually healed after removal of the nail and screws, débridement, and immobilization with an external fixator. Based on this experience, we concluded that this form of treatment has many advantages. The risk of infection and non-union is low, the incidence and severity of malunion are reduced, the hospital stay is short, and early mobilization of the patient is possible.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Retrograde Versus Antegrade Nailing of Femoral Shaft Fractures
Ricci, W. M., Bellabarba, C., Evanoff, B., Herscovici, D., DiPasquale, T., & Sanders, R. (2001) · Journal of Orthopaedic Trauma · doi:10.1097/00005131-200103000-00003 · Cited by 280
Glatt, V., Evans, C. H., & Tetsworth, K. (2017) · Frontiers in Physiology · doi:10.3389/fphys.2016.00678 · Cited by 194
Metadata
- Authors
- Kempf, I., Grosse, A., & Beck, G.
- Venue
- The Journal of Bone & Joint Surgery
- Published
- 1985-06
- Volume
- 67
- Issue
- 5
- Pages
- 709-720
- ISSN
- 0021-9355 (ISSN-L)
- OpenAlex
- W1908491907
- Cited by
- 552
- References
- 0
- FWCI
- 3.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Closed locked intramedullary nailing. Its application to comminuted fractures of the femur. https://app.cochat.ai/papers/10.2106/00004623-198567050-00005
- The paper
- Kempf, I., Grosse, A., & Beck, G. (1985). Closed locked intramedullary nailing. Its application to comminuted fractures of the femur. The Journal of Bone & Joint Surgery. https://doi.org/10.2106/00004623-198567050-00005
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.