The DOI matches its Crossref record.
Porous hydroxyapatite as a bone-graft substitute in metaphyseal defects. A histometric study.
Abstract
Porous hydroxyapatite (Interpore 500) formed by conversion of the Porites goniopora coral exoskeleton has pores averaging 600 micrometers and pore interconnections averaging 260 micrometers in diameter. In the proximal tibial metaphysis of eight dogs, a defect one cubic centimeter in size was created unilaterally and was fitted with a block of Interpore 500. Both proximal tibial metaphyses were retrieved at two, four, six, and twelve months. Stained undecalcified sections were examined by light microscopy and quantitated by histometric methods. The implant-side specimens contained compact bone along the external surface and trabecular bone interiorly. The interior of these specimens was composed of 51.9 +/- 1.3 per cent soft tissue, 13.0 +/- 1.2 per cent bone, and 35.1 +/- 1.2 per cent Interpore 500 (mean and standard error). The interior of the normal specimens was composed of 79.7 +/- 1.4 per cent soft tissue and 20.2 +/- 1.4 per cent bone. The allocation of implant pore space between bone and soft tissue was proportional to that of bone and soft tissue in the normal tibiae. The stereological distribution of regenerated bone in the porous hydroxyapatite was also the same as in the normal tibiae. The appositional process of incorporation of the implant was confirmed by the finding that 66.5 per cent of the surface of the Interpore 500 was covered with bone ingrowth at twelve months.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bone graft and bone graft substitutes: A review of current technology and applications
Damien, C. J., & Parsons, J. R. (1991) · Journal of Applied Biomaterials · doi:10.1002/jab.770020307 · Cited by 1,058
THE ROLE OF GROWTH FACTORS IN THE REPAIR OF BONE: BIOLOGY AND CLINICAL APPLICATIONS
LIEBERMAN, J. R., DALUISKI, A., & EINHORN, T. A. (2002) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200206000-00022 · Cited by 932
Fernandez de Grado, G., Keller, L., Idoux-Gillet, Y., Wagner, Q., Musset, A.-M., Benkirane-Jessel, N., Bornert, F., & Offner, D. (2018) · Journal of Tissue Engineering · doi:10.1177/2041731418776819 · Cited by 912
Taboas, J. M., Maddox, R. D., Krebsbach, P. H., & Hollister, S. J. (2003) · Biomaterials · doi:10.1016/s0142-9612(02)00276-4 · Cited by 691
Electrospun nanostructured scaffolds for bone tissue engineering
Prabhakaran, M. P., Venugopal, J., & Ramakrishna, S. (2009) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.05.007 · Cited by 430
Metadata
- Authors
- Holmes, R. E., Bucholz, R. W., & Mooney, V
- Venue
- The Journal of Bone & Joint Surgery
- Published
- 1986-07
- Volume
- 68
- Issue
- 6
- Pages
- 904-911
- ISSN
- 0021-9355 (ISSN-L)
- OpenAlex
- W2143797170
- Cited by
- 305
- References
- 0
- FWCI
- 8.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Porous hydroxyapatite as a bone-graft substitute in metaphyseal defects. A histometric study. https://app.cochat.ai/papers/10.2106/00004623-198668060-00013
- The paper
- Holmes, R. E., Bucholz, R. W., & Mooney, V. (1986). Porous hydroxyapatite as a bone-graft substitute in metaphyseal defects. A histometric study. The Journal of Bone & Joint Surgery. https://doi.org/10.2106/00004623-198668060-00013
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.