The DOI matches its Crossref record.
Release of gentamicin from acrylic bone cement. Elution and diffusion studies.
Abstract
It has been generally assumed that release of antibiotic from methylmethacrylate occurs either from the surface, through pores in the matrix of the cement, or by diffusion through the matrix. In vitro and in vivo studies of the release of antibiotic from cement have produced variable and inconsistent results. In our laboratory, preliminary observations suggested that antibiotic is released from methylmethacrylate by flow through an interconnecting series of voids and cracks in the cement, rather than through diffusion after having been homogeneously distributed throughout the cement. Therefore, experiments were performed to answer the fundamental question of whether the matrix of methylmethacrylate bone cement is permeable to gentamicin. In vivo elution studies were performed on injection-molded rods of methylmethacrylate that had been loaded with two different amounts of gentamicin. The first group of rods contained 0.5 gram of gentamicin for each packet and the second, 1.5 grams for each packet. The rods were embedded subcutaneously in the subcostal region of sheep for three months. Bioassay of sections of the rods, using the tube-diffusion technique of Mitchison and Spicer, showed that the more highly loaded cement had released a significantly greater proportion of gentamicin. This occurred because the more highly loaded cement contained a greater number of defects that contained gentamicin (filled voids and interconnecting cracks). In vitro diffusion studies were also performed, using 0.8-millimeter-thick disks of methylmethacrylate that did not contain antibiotic. Test solutions of either gentamicin or methylene blue were placed in the inner compartments of diffusion chambers. The outer compartments contained tissue-culture medium 199, which was sampled monthly and assayed for gentamicin or methylene blue.(ABSTRACT TRUNCATED AT 250 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Concise review of mechanisms of bacterial adhesion to biomaterial surfaces
An, Y. H., & Friedman, R. J. (1998) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199823)43:3<338::aid-jbm16>3.0.co;2-b · Cited by 1,146
HANSSEN, A. D., & RAND, J. A. (1998) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199806000-00016 · Cited by 445
ANTIBIOTIC-LOADED BONE CEMENT FOR INFECTION PROPHYLAXIS IN TOTAL JOINT REPLACEMENT
JIRANEK, W. A., HANSSEN, A. D., & GREENWALD, A. S. (2006) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200611000-00024 · Cited by 411
Mesoporous SBA-15 HPLC evaluation for controlled gentamicin drug delivery
Doadrio, A. L., Sousa, E. M. B., Doadrio, J. C., Pérez Pariente, J., Izquierdo-Barba, I., & Vallet-Regı́, M. (2004) · Journal of Controlled Release · doi:10.1016/j.jconrel.2004.03.005 · Cited by 374
Long-term elution of antibiotics from bone-cement
Masri, B. A., Duncan, C. P., & Beauchamp, C. P. (1998) · The Journal of Arthroplasty · doi:10.1016/s0883-5403(98)90179-6 · Cited by 356
Metadata
- Authors
- Baker, A. S., & Greenham, L. W.
- Venue
- The Journal of Bone & Joint Surgery
- Published
- 1988-12
- Volume
- 70
- Issue
- 10
- Pages
- 1551-1557
- ISSN
- 0021-9355 (ISSN-L)
- OpenAlex
- W4301224389
- Cited by
- 194
- References
- 0
- FWCI
- 0.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Release of gentamicin from acrylic bone cement. Elution and diffusion studies. https://app.cochat.ai/papers/10.2106/00004623-198870100-00015
- The paper
- Baker, A. S., & Greenham, L. W. (1988). Release of gentamicin from acrylic bone cement. Elution and diffusion studies. The Journal of Bone & Joint Surgery. https://doi.org/10.2106/00004623-198870100-00015
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.