Infection after intramedullary nailing of severe open tibial fractures initially treated with external fixation.
The DOI matches its Crossref record.
Abstract
Twenty-four patients had a severe open fracture of the tibia that was initially treated by external fixation and subsequently by reamed intramedullary nailing. The external fixation had been maintained for an average of fifty-two days (range, seven to 230 days). The mean interval between removal of the external fixator and intramedullary nailing was sixty-five days (range, three to 360 days). In five of the seven patients who had had an infection at one or more of the pin sites, an infection later developed around the intramedullary nail. In comparison, only one of the seventeen patients who had not had a pin-site infection had an infection later around the nail (p = 0.003). An analysis of other variables, including the duration of external fixation, wound coverage, other injuries, and the type of fracture, showed that none was a predictor of infection either at the pin sites or around the intramedullary nail. We concluded that a pin-site infection that develops during external fixation is a contraindication to the subsequent use of reamed intramedullary nailing in patients who have a fracture of the tibia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Staphylococci and implant surfaces: a review
Harris, L. G., & Richards, R. G. (2006) · Injury · doi:10.1016/j.injury.2006.04.003 · Cited by 385
NOWOTARSKI, P. J., TUREN, C. H., BRUMBACK, R. J., & SCARBORO, J. M. (2000) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200006000-00004 · Cited by 326
Studies of photokilling of bacteria using titanium dioxide nanoparticles
Tsuang, Y., Sun, J., Huang, Y., Lu, C., Chang, W. H., & Wang, C. (2008) · Artificial Organs · doi:10.1111/j.1525-1594.2007.00530.x · Cited by 247
Pin Tract Infection With Contemporary External Fixation: How Much of a Problem?
Parameswaran, A. D., Roberts, C. S., Seligson, D., & Voor, M. (2003) · Journal of Orthopaedic Trauma · doi:10.1097/00005131-200308000-00005 · Cited by 231
“Infected external fixation pins also increase the complication rate when intramedullary nailing procedures follow external fixation.(6) Contemporary techniques of external fixation using either manually inserted self-drilling half-pins, tapered pins used after drilling a pilot hole, prophylactic oral antibiotics, and…”
BackgroundIntramedullary Nailing Following External Fixation in Femoral and Tibial Shaft Fractures
Bhandari, M., Zlowodzki, M., Tornetta, P., Schmidt, A., & Templeman, D. C. (2005) · Journal of Orthopaedic Trauma · doi:10.1097/00005131-200502000-00012 · Cited by 195
The use of gentamicin-coated nails in the tibia: preliminary results of a prospective study
Fuchs, T., Stange, R., Schmidmaier, G., & Raschke, M. J. (2011) · Archives of Orthopaedic and Trauma Surgery · doi:10.1007/s00402-011-1321-6 · Cited by 192
“No deep wound infections were observed in our patients who showed greater complexity than those evaluated in previous studies of intramedullary tibial nailing [5, 9, 14].”
Result
Metadata
- Authors
- Maurer, D. J., Merkow, R. L., & Gustilo, R. B.
- Venue
- The Journal of Bone & Joint Surgery
- Published
- 1989-07
- Volume
- 71
- Issue
- 6
- Pages
- 835-838
- ISSN
- 0021-9355 (ISSN-L)
- OpenAlex
- W2230785882
- Cited by
- 193
- References
- 0
- FWCI
- 2.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.