The DOI matches its Crossref record.
The use of quantitative computed tomography to estimate risk of fracture of the hip from falls.
Abstract
We conducted an in vitro investigation of the loads and energies needed to fracture the proximal part of the femur in twelve fresh cadavera under loading conditions simulating one particular type of fall. The fracture loads ranged from 778 to 4,040 newtons and the work to fracture, from five to fifty-one joules. We also investigated the relationship between the fracture loads and several potential indices of bone strength, which were measured non-invasively at the subcapital, basic-cervical, and intertrochanteric regions with quantitative computed tomography. A very high positive correlation with the fracture load resulted from use of an intertrochanteric index--the product of the average trabecular computed-tomography number and the total cross-sectional area of the bone (R2 = 0.93, standard error of estimate = 295 newtons, and p less than 0.00001). We expect the use of this parameter to result in improved assessments of the degree of osteoporosis and of the component of risk of fracture of the hip that is associated with bone strength. However, the measured work to fracture for the isolated femur was an order of magnitude smaller than estimates of the energy available during a typical fall (about 450 joules), suggesting that energy absorbed during falling and impact, rather than bone strength, may be the dominant factors in the biomechanics of fracture of the hip.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
New approaches for interpreting projected bone densitometry data
Professor Carter, D. R., Bouxsein, M. L., & Marcus, R. (1992) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650070204 · Cited by 1,065
Risk Factors for Falls as a Cause of Hip Fracture in Women
Grisso, J. A., Kelsey, J. L., Strom, B. L., Ghiu, G. Y., Maislin, G., O'Brien, L. A., Hoffman, S., & Kaplan, F. (1991) · New England Journal of Medicine · doi:10.1056/nejm199105093241905 · Cited by 862
Clinical Use of Bone Densitometry: Scientific Review
Cummings, S. R., Bates, D., & Black, D. M. (2002) · JAMA · doi:10.1001/jama.288.15.1889 · Cited by 817
Dependence of yield strain of human trabecular bone on anatomic site
Morgan, E. F., & Keaveny, T. M. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00011-2 · Cited by 705
Falls Among Older Persons: A Public Health Perspective
Sattin, R. W. (1992) · Annual Review of Public Health · doi:10.1146/annurev.pu.13.050192.002421 · Cited by 687
Metadata
- Authors
- Lotz, J. C., & Hayes, W. C.
- Venue
- The Journal of Bone & Joint Surgery
- Published
- 1990-06
- Volume
- 72
- Issue
- 5
- Pages
- 689-700
- ISSN
- 0021-9355 (ISSN-L)
- OpenAlex
- W2248423827
- Cited by
- 243
- References
- 0
- FWCI
- 7.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The use of quantitative computed tomography to estimate risk of fracture of the hip from falls. https://app.cochat.ai/papers/10.2106/00004623-199072050-00008
- The paper
- Lotz, J. C., & Hayes, W. C. (1990). The use of quantitative computed tomography to estimate risk of fracture of the hip from falls. The Journal of Bone & Joint Surgery. https://doi.org/10.2106/00004623-199072050-00008
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.