Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 202

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Direct in vitro measurement of forces in the cruciate ligaments. Part I: The effect of multiplane loading in the intact knee.

Wascher, D C, Markolf, K L, Shapiro, M S, Finerman, G A·1993·The Journal of Bone & Joint Surgery

Abstract

Specially designed load-transducers that measured the resultant forces exerted by the posterior and anterior cruciate ligaments on their respective femoral and tibial insertions were applied to eighteen fresh-frozen cadaveric knees for a series of controlled loading experiments. The mean force in the posterior cruciate ligament at 5 degrees of forced hyperextension of the knee was 23 per cent of the mean force in the anterior cruciate ligament. When the knee was hyperflexed by application of 10.0 newton-meters of bending moment to the tibia, the mean force in the posterior cruciate ligament was 55 per cent of that in the anterior cruciate ligament. Quadriceps tendon pull increased the force in the posterior cruciate ligament in twelve of the fourteen specimens to which it had been applied, at 80 and 90 degrees of flexion only. The force generated in the posterior cruciate ligament by applied internal tibial torque was greatest when the knee was in 90 degrees of flexion; the force in the anterior cruciate ligament was greatest when the knee was fully extended. External tibial torque generated force in the posterior cruciate ligament in only eight specimens, and only at 80 and 90 degrees of flexion. The levels of force that were generated in the posterior cruciate ligament by applied varus and valgus bending moment were greatest at 90 degrees of flexion of the knee; the levels of force in the anterior cruciate ligament were greatest with the knee in full extension. With the knee flexed 90 degrees and the tibia in neutral rotation, fifty newtons of applied posterior tibial force increased the mean force in the posterior cruciate ligament by 58.4 newtons; at full extension, no increase in the force in the ligament was recorded, indicating that tensed capsular structures were absorbing the applied load. When the tibia was internally or externally rotated by applied tibial torque, the increases in the force in the ligament from applied posterior tibial force were sharply diminished.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2106/00004623-199303000-00009

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 202

Metadata

Authors
Wascher, D. C., Markolf, K. L., Shapiro, M. S., & Finerman, G. A.
Venue
The Journal of Bone & Joint Surgery
Published
1993-03
Volume
75
Issue
3
Pages
377-386
ISSN
0021-9355 (ISSN-L)
OpenAlex
W1936669332
Cited by
202
References
1
FWCI
12.43
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Direct in vitro measurement of forces in the cruciate ligaments. Part I: The effect of multiplane loading in the intact knee. https://app.cochat.ai/papers/10.2106/00004623-199303000-00009
The paper
Wascher, D. C., Markolf, K. L., Shapiro, M. S., & Finerman, G. A. (1993). Direct in vitro measurement of forces in the cruciate ligaments. Part I: The effect of multiplane loading in the intact knee. The Journal of Bone & Joint Surgery. https://doi.org/10.2106/00004623-199303000-00009

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.