The DOI matches its Crossref record.
Fixation with bioabsorbable screws for the treatment of fractures of the ankle.
Abstract
One hundred and fifty-five patients who had a closed, displaced medial malleolar, bimalleolar, or trimalleolar fracture of the ankle were managed with medial malleolar fixation with use of either 4.0-millimeter orientruded polylactide screws (eighty-three patients, study group) or 4.0-millimeter stainless-steel screws (seventy-two patients, control group). All lateral malleolar fractures were stabilized with standard metallic implants. At an average of thirty-seven months (range, twenty-one to fifty-nine months), the radiographic and functional results in the two groups were equivalent. Differences between the two groups with regard to the rates of operative and postoperative complications were not statistically significant. Late spontaneous drainage of the hydrolyzed polylactide was not noted in any patient in the study group. The prevalence of late tenderness over the medial malleolar implant was lower in the patients in whom the fracture had been stabilized with polylactide screws. We conclude that polylactide screws are a safe and effective alternative to stainless-steel screws for the fixation of displaced medial malleolar fractures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Farah, S., Anderson, D. G., & Langer, R. (2016) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2016.06.012 · Cited by 3,443
Poly(lactic acid) modifications
Rasal, R. M., Janorkar, A. V., & Hirt, D. E. (2010) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2009.12.003 · Cited by 2,204
Athanasiou, K. A., Niederauer, G. G., & Agrawal, C. M. (1996) · Biomaterials · doi:10.1016/0142-9612(96)85754-1 · Cited by 1,497
Properties and medical applications of polylactic acid: A review
Hamad, K., Kaseem, M., Yang, H. W., Deri, F., & Ko, Y. G. (2015) · Express Polymer Letters · doi:10.3144/expresspolymlett.2015.42 · Cited by 722
Michelson, J. D. (1995) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199501000-00020 · Cited by 275
Metadata
- Authors
- Bucholz, R. W., Henry, S., & Henley, M. B.
- Venue
- The Journal of Bone & Joint Surgery
- Published
- 1994-03
- Volume
- 76
- Issue
- 3
- Pages
- 319-324
- ISSN
- 0021-9355 (ISSN-L)
- OpenAlex
- W2231775894
- Cited by
- 271
- References
- 0
- FWCI
- 11.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fixation with bioabsorbable screws for the treatment of fractures of the ankle. https://app.cochat.ai/papers/10.2106/00004623-199403000-00001
- The paper
- Bucholz, R. W., Henry, S., & Henley, M. B. (1994). Fixation with bioabsorbable screws for the treatment of fractures of the ankle. The Journal of Bone & Joint Surgery. https://doi.org/10.2106/00004623-199403000-00001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.