Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 159

The DOI matches its Crossref record.

Use of allografts after failed treatment of rupture of the anterior cruciate ligament.

Noyes, F R, Barber-Westin, S D, Roberts, C S · 1994 · The Journal of Bone & Joint Surgery

Abstract

A prospective study was done of the use of allogeneic tissue to reconstruct the anterior cruciate ligament in knees in which an intra-articular or an extra-articular operation had failed. Sixty-six consecutive patients (sixty-six knees) had such an operation with use of bone-patellar ligament-bone allografts; all but one returned for follow-up evaluation twenty-three to seventy-eight months (mean, forty-two months) after the operation. A total of 235 previous operations had been performed in these sixty-six knees, including eighty-one procedures for rupture of the anterior cruciate ligament. The results of the allograft procedure were evaluated with a subjective and objective system that rated twenty factors. The anterior-posterior displacement was substantially improved in most of the patients. According to data derived from arthrometric studies and pivot-shift tests of the fifty-seven patients who were so evaluated and in whom the condition was unilateral, 53 per cent (thirty) of the reconstructed ligaments were determined to be functional; 21 per cent (twelve ligaments), partially functional; and 26 per cent (fifteen ligaments), a failure. When we calculated the rate of failure by including ten failures that had occurred within two years after the operation with the fifteen that occurred in patients who had been followed for at least two years, the over-all rate of failure was 33 per cent (twenty-five of seventy-five operations). There was significant improvement in the subjective ratings of functional limitations and symptoms (p < 0.01) and in the over-all rating score (p < 0.0001). However, there was a significant difference between the scores of the patients in whom the surfaces of the articular cartilage had appeared normal at the index operation and those of the patients in whom there had been noteworthy fissuring and fragmentation or exposure of subchondral bone. After the program of rehabilitation, which included immediate motion of the knee, a range of motion of 0 to 135 degrees was restored in all but five knees, four of which lacked only 5 degrees of this extent of flexion or extension. The results demonstrate that bone-patellar ligament-bone allografts may be used when proper autogenous tissues are not available and that symptoms and abnormal displacement were reduced in most of our patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2106/00004623-199407000-00010

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 159

Metadata

Authors
Noyes, F. R., Barber-Westin, S. D., & Roberts, C. S.
Venue
The Journal of Bone & Joint Surgery
Published
1994-07
Volume
76
Issue
7
Pages
1019-1031
ISSN
0021-9355 (ISSN-L)
OpenAlex
W1936305065
Cited by
159
References
0
FWCI
5.76
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Use of allografts after failed treatment of rupture of the anterior cruciate ligament. https://app.cochat.ai/papers/10.2106/00004623-199407000-00010
The paper
Noyes, F. R., Barber-Westin, S. D., & Roberts, C. S. (1994). Use of allografts after failed treatment of rupture of the anterior cruciate ligament. The Journal of Bone & Joint Surgery. https://doi.org/10.2106/00004623-199407000-00010

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.