Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 445

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

The tibiofibular syndesmosis. Evaluation of the ligamentous structures, methods of fixation, and radiographic assessment.

Xenos, J S, Hopkinson, W J, Mulligan, M E, Olson, E J, Popovic, N A·1995·The Journal of Bone & Joint Surgery

Abstract

Twenty-five fresh-frozen cadaveric specimens were used to evaluate the role of the syndesmotic ligaments when the ankle is loaded with external rotation torque. An apparatus was constructed that allowed pure external-rotation torque to be applied through the ankle with the foot in neutral flexion. The apparatus provided solid fixation of the tibia while allowing free movement of the fibula in all planes. The syndesmotic ligaments were incrementally sectioned, and direct measurements of anatomical diastasis were made. Mortise and lateral radiographs were made at each increment under both loaded (5.0 newton-meters) and unloaded conditions. After all structures of the syndesmosis had been divided, the syndesmosis was reduced and was repaired with one or two screws. The strength of the repair was measured with incremental increases in torque of 1.0 newton-meter. The radiographs were measured by three independent observers in a blind fashion. In order to evaluate intraobserver error, each observer was randomly given forty radiographs to reinterpret. Diastasis and rotation were found to be related to the amount of injury of the ligament (p < 0.0001). After the entire syndesmosis had been divided, application of a 5.0-newton-meter torque resulted in a mean diastasis of 7.3 millimeters. The subsequent repair of the anterior tibiofibular ligament with suture failed at a mean of 2.0 newton-meters (range, 1.0 to 6.0 newton-meters) of torque. Repair with two screws was found to be stronger than repair with one, with the first construct failing at a mean of 11.0 newton-meters (range, 5.0 to 15.0 newton-meters) and the second, at a mean of 6.2 newton-meters (range, 2.0 to 10.0 newton-meters) (p = 0.0005). Failure of the screw fixation was not associated with the maximum previous diastasis (p = 0.13). Measurements of anatomical diastasis were compared with measurements made on the mortise and lateral radiographs. Measurements on the stress mortise radiographs had a weak correlation with diastasis (r = 0.41, p < 0.0001). However, measurements on the stress lateral radiographs had a higher correlation (r = 0.81, p < 0.0001). Additionally, interobserver correlation was significantly higher for the measurements on the lateral radiographs (r = 0.87, p < 0.0001) than for those on the mortise radiographs (r = 0.56, p < 0.0001). Intraobserver correlation for the three observers was poor with regard to the measurements on the mortise radiographs (r = 0.12, 0.42, and 0.25). The respective correlations for the measurements on the lateral radiographs were r = 0.81, 0.90, and 0.89.(ABSTRACT TRUNCATED AT 400 WORDS)

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2106/00004623-199506000-00005

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 445

Metadata

Authors
Xenos, J. S., Hopkinson, W. J., Mulligan, M. E., Olson, E. J., & Popovic, N. A.
Venue
The Journal of Bone & Joint Surgery
Published
1995-06
Volume
77
Issue
6
Pages
847-856
ISSN
0021-9355 (ISSN-L)
OpenAlex
W2105862447
Cited by
445
References
7
FWCI
1.96
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The tibiofibular syndesmosis. Evaluation of the ligamentous structures, methods of fixation, and radiographic assessment. https://app.cochat.ai/papers/10.2106/00004623-199506000-00005
The paper
Xenos, J. S., Hopkinson, W. J., Mulligan, M. E., Olson, E. J., & Popovic, N. A. (1995). The tibiofibular syndesmosis. Evaluation of the ligamentous structures, methods of fixation, and radiographic assessment. The Journal of Bone & Joint Surgery. https://doi.org/10.2106/00004623-199506000-00005

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.