The DOI matches its Crossref record.
The influence of surface-blasting on the incorporation of titanium-alloy implants in a rabbit intramedullary model.
Abstract
The apposition of new bone to polished solid implants and to implants with surfaces that had been blasted with one of three methods of grit-blasting was studied in a rabbit intramedullary model to test the hypothesis that blasted implant surfaces support osseous integration. Intramedullary titanium-alloy (Ti-6Al-4V) plugs, press-fit into the distal aspect of the femoral canal, were implanted bilaterally in fifty-six rabbits. Four surface treatments were studied: polished (a surface roughness of 0.4 to 0.6 micrometer) and blasted with stainless-steel shot (a surface roughness of five to seven micrometers), with thirty-six-grit aluminum oxide (a surface roughness of five to seven micrometers), or with sixty-grit aluminum oxide (a surface roughness of three to five micrometers). Localized attachment of new bone to the surfaces of the blasted implants was present radiographically at twelve weeks. The total bone area was significantly affected by the level of the section (the diaphysis had a greater bone area than the proximal part of the metaphysis and the proximal part of the metaphysis had a greater bone area than the distal part of the metaphysis; p < 0.001) and the quadrant within each section (the posterior and anterior quadrants had greater bone area than the medial and lateral quadrants; p < 0.00001). The length of the bone-implant interface was significantly affected by the surface treatment (the length of the bone-implant interface for the implants that had been blasted with sixty-grit aluminum oxide was greater than the length for the polished implants; p = 0.02), the time after implantation (the interface was longer at six and twelve weeks than at three weeks; p < 0.00001), and the level of the section (the interface was longer at the diaphysis than at the proximal part of the metaphysis and longer at the proximal part of the metaphysis than at the distal part of the metaphysis; p = 0.004). Blasting of the surface of titanium-alloy implants did not have an effect on the area of bone formation around the implants, but it did significantly affect the area of bone formation on the implant and the shear strength at the bone-implant interface. The two effects were not necessarily parallel, as significantly less (p < 0.05) bone formed on implants that had been blasted with stainless-steel shot than on those blasted with aluminum grit, whereas their interface shear strengths were similar.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Eliaz, N., & Metoki, N. (2017) · Materials · doi:10.3390/ma10040334 · Cited by 1,088
Significance of calcium phosphate coatings for the enhancement of new bone osteogenesis – A review
Surmenev, R. A., Surmeneva, M. A., & Ivanova, A. A. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.10.036 · Cited by 712
A role for surface topography in creating and maintaining bone at titanium endosseous implants
Cooper, L. F. (2000) · The Journal of Prosthetic Dentistry · doi:10.1067/mpr.2000.111966 · Cited by 336
Aparicio, C., Javier Gil, F., Fonseca, C., Barbosa, M., & Planell, J. A. (2003) · Biomaterials · doi:10.1016/s0142-9612(02)00314-9 · Cited by 298
Refai, A. K., Textor, M., Brunette, D. M., & Waterfield, J. D. (2004) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30075 · Cited by 296
Metadata
- Authors
- Feighan, J. E., Goldberg, V. M., Davy, D., Parr, J. A., & Stevenson, S.
- Venue
- The Journal of Bone & Joint Surgery
- Published
- 1995-09
- Volume
- 77
- Issue
- 9
- Pages
- 1380-1395
- ISSN
- 0021-9355 (ISSN-L)
- OpenAlex
- W1948715372
- Cited by
- 176
- References
- 0
- FWCI
- 2.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The influence of surface-blasting on the incorporation of titanium-alloy implants in a rabbit intramedullary model. https://app.cochat.ai/papers/10.2106/00004623-199509000-00015
- The paper
- Feighan, J. E., Goldberg, V. M., Davy, D., Parr, J. A., & Stevenson, S. (1995). The influence of surface-blasting on the incorporation of titanium-alloy implants in a rabbit intramedullary model. The Journal of Bone & Joint Surgery. https://doi.org/10.2106/00004623-199509000-00015
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.