Comparison of the Use of a Foot Pump with the Use of Low-Molecular-Weight Heparin for the Prevention of Deep-Vein Thrombosis after Total Hip Replacement. A Prospective, Randomized Trial*

WARWICK, DAVID, HARRISON, JEFFREY, GLEW, DAVID, MITCHELMORE, ANDREW, PETERS, TIM J., DONOVAN, JENNY · 1998 · The Journal of Bone & Joint Surgery

Abstract

We conducted a prospective, randomized trial to compare the safety and effectiveness of the A-V Impulse System foot pump with that of low-molecular-weight heparin for reducing the prevalence of deep-vein thrombosis after total hip replacement. Of 290 patients who were to have a primary total hip replacement, 143 were randomized to receive enoxaparin (forty milligrams daily) for seven days after the operation and 147, to use the foot pump for seven days. The primary outcome measure was the prevalence of deep-vein thrombosis, as determined by venography on the sixth, seventh, or eighth postoperative day. Secondary outcome measures included transfusion requirements, intraoperative blood loss, postoperative drainage, blood-loss index, appearance of the site of the wound according to a subjective visual-analog scale, and swelling of the thigh. The patients' compliance with the regimen for use of the foot pump was monitored with an internal timing device, and their acceptance of the device was assessed with a questionnaire. Symptoms consistent with pulmonary embolism were investigated with ventilation-perfusion scanning. The patients were contacted later for detection of symptoms of venous thromboembolism that may have occurred during the first three months after discharge from the hospital. Venography was performed on 274 patients: 136 who used the foot pump and 138 who received enoxaparin. Deep-vein thrombosis was detected in twenty-four (18 per cent) of the patients who used the foot pump compared with eighteen patients (13 per cent) who received enoxaparin (95 per cent confidence interval for the difference in proportions, -3.9 to +13.0 per cent). Thrombosis in the calf was found in seven patients (5 per cent) in the former group compared with six patients (4 per cent) in the latter (95 per cent confidence interval for the difference, -4.2 to +5.8 per cent), and proximal thrombosis was observed in seventeen patients (13 per cent) in the former group compared with twelve patients (9 per cent) in the latter (95 per cent confidence interval for the difference, -3.5 to +11.1 per cent). None of these differences was significant. No patient in either group had major proximal deep-vein thrombosis; all proximal thrombi were isolated entities involving the femoral valve cusp and were of unknown importance. One patient who used the foot pump had a non-fatal pulmonary embolism. One patient who received enoxaparin had a symptomatic deep-vein thrombosis during hospitalization. Two patients (one from each group [0.7 per cent]) were readmitted to the hospital because of a symptomatic deep-vein thrombosis despite normal venographic findings at the time of discharge. There was no difference in the transfusion requirements or the intraoperative blood loss between the two groups. There were more soft-tissue side effects in the patients who received enoxaparin than in those who used the foot pump: there was more bruising of the thigh and oozing of the wound (p < 0.001 for each), postoperative drainage (578 compared with 492 milliliters; p = 0.014), and swelling of the thigh (twenty compared with ten millimeters; p = 0.03). Of 124 patients who used the foot pump and were asked about the acceptability of the device, fourteen (11 per cent) said that it was uncomfortable, twenty-one (17 per cent) reported sleep disturbance, and four (3 per cent) stated that they had stopped using the device. Conversely, ten (8 per cent) found it relaxing. We concluded that the foot pump is a suitable alternative to low-molecular-weight heparin for prophylaxis against thromboembolism after total hip replacement and that it produces fewer soft-tissue side effects. Tolerance of the device is a problem for some patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2106/00004623-199808000-00009

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 197

Metadata

Authors
WARWICK, D., HARRISON, J., GLEW, D., MITCHELMORE, A., PETERS, T. J., & DONOVAN, J.
Venue
The Journal of Bone & Joint Surgery
Published
1998-08
Volume
80
Issue
8
Pages
1158-66
ISSN
0021-9355 (ISSN-L)
OpenAlex
W2102868827
Cited by
197
References
1
FWCI
7.35
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of the Use of a Foot Pump with the Use of Low-Molecular-Weight Heparin for the Prevention of Deep-Vein Thrombosis after Total Hip Replacement. A Prospective, Randomized Trial*. https://app.cochat.ai/papers/10.2106/00004623-199808000-00009
The paper
WARWICK, D., HARRISON, J., GLEW, D., MITCHELMORE, A., PETERS, T. J., & DONOVAN, J. (1998). Comparison of the Use of a Foot Pump with the Use of Low-Molecular-Weight Heparin for the Prevention of Deep-Vein Thrombosis after Total Hip Replacement. A Prospective, Randomized Trial*. The Journal of Bone & Joint Surgery. https://doi.org/10.2106/00004623-199808000-00009

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.