Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 465

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Experimental Rotator Cuff Repair. A Preliminary Study*

GERBER, CHRISTIAN, SCHNEEBERGER, ALBERTO G., PERREN, STEPHAN M., NYFFELER, RICHARD W.·1999·The Journal of Bone & Joint Surgery

Abstract

BACKGROUND: The repair of chronic, massive rotator cuff tears is associated with a high rate of failure. Prospective studies comparing different repair techniques are difficult to design and carry out because of the many factors that influence structural and clinical outcomes. The objective of this study was to develop a suitable animal model for evaluation of the efficacy of different repair techniques for massive rotator cuff tears and to use this model to compare a new repair technique, tested in vitro, with the conventional technique. METHODS: We compared two techniques of rotator cuff repair in vivo using the left shoulders of forty-seven sheep. With the conventional technique, simple stitches were used and both suture ends were passed transosseously and tied over the greater tuberosity of the humerus. With the other technique, the modified Mason-Allen stitch was used and both suture ends were passed transosseously and tied over a cortical-bone-augmentation device. This device consisted of a poly(L/D-lactide) plate that was fifteen millimeters long, ten millimeters wide, and two millimeters thick. Number-3 braided polyester suture material was used in all of the experiments. RESULTS: In pilot studies (without prevention of full weight-bearing), most repairs failed regardless of the technique that was used. The simple stitch always failed by the suture pulling through the tendon or the bone; the suture material did not break or tear. The modified Mason-Allen stitch failed in only two of seventeen shoulders. In ten shoulders, the suture material failed even though the stitches were intact. Thus, we concluded that the modified Mason-Allen stitch is a more secure method of achieving suture purchase in the tendon. In eight of sixteen shoulders, the nonaugmented double transosseous bone-fixation technique failed by the suture pulling through the bone. The cortical-bone-augmentation technique never failed. In definite studies, prevention of full weight-bearing was achieved by fixation of a ten-centimeter-diameter ball under the hoof of the sheep. This led to healing in eight of ten shoulders repaired with the modified Mason-Allen stitch and cortical-bone augmentation. On histological analysis, both the simple-stitch and the modified Mason-Allen technique caused similar degrees of transient localized tissue damage. Mechanical pullout tests of repairs with the new technique showed a failure strength that was approximately 30 percent of that of an intact infraspinatus tendon at six weeks, 52 percent of that of an intact tendon at three months, and 81 percent of that of an intact tendon at six months. CONCLUSIONS: The repair technique with a modified Mason-Allen stitch with number-3 braided polyester suture material and cortical-bone augmentation was superior to the conventional repair technique. Use of the modified Mason-Allen stitch and the cortical-bone-augmentation device transferred the weakest point of the repair to the suture material rather than to the bone or the tendon. Failure to protect the rotator cuff post-operatively was associated with an exceedingly high rate of failure, even if optimum repair technique was used. CLINICAL RELEVANCE: Different techniques for rotator cuff repair substantially influence the rate of failure. A modified Mason-Allen stitch does not cause tendon necrosis, and use of this stitch with cortical-bone augmentation yields a repair that is biologically well tolerated and stronger in vivo than a repair with the conventional technique. Unprotected repairs, however, have an exceedingly high rate of failure even if optimum repair technique is used. Postoperative protection from tension overload, such as with an abduction splint, may be necessary for successful healing of massive rotator cuff tears.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2106/00004623-199909000-00009

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 465

Metadata

Authors
GERBER, C., SCHNEEBERGER, A. G., PERREN, S. M., & NYFFELER, R. W.
Venue
The Journal of Bone & Joint Surgery
Published
1999-09
Volume
81
Issue
9
Pages
1281-90
ISSN
0021-9355 (ISSN-L)
OpenAlex
W2138606995
Cited by
465
References
6
FWCI
6.16
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Experimental Rotator Cuff Repair. A Preliminary Study*. https://app.cochat.ai/papers/10.2106/00004623-199909000-00009
The paper
GERBER, C., SCHNEEBERGER, A. G., PERREN, S. M., & NYFFELER, R. W. (1999). Experimental Rotator Cuff Repair. A Preliminary Study*. The Journal of Bone & Joint Surgery. https://doi.org/10.2106/00004623-199909000-00009

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.