The DOI matches its Crossref record.
The Use of Fibrin Tissue Adhesive to Reduce Blood Loss and the Need for Blood Transfusion After Total Knee Arthroplasty. A Prospective, Randomized, Multicenter Study*
Abstract
BACKGROUND: Total knee arthroplasty is associated with major postoperative blood loss of approximately 800 to 1200 milliliters, and blood transfusion is frequently required. With the increased concern about the risks of blood transfusion, various methods of blood conservation in orthopaedic surgery have been studied. The most appropriate solution, however, is to reduce the loss of blood during and after an operation. The present prospective, controlled, randomized study was designed to evaluate the hemostatic efficacy of the use of fibrin tissue adhesive in patients managed with total knee arthroplasty. METHODS: Fifty-eight patients who were scheduled to have a total knee arthroplasty were randomly divided into two groups: a control group, in which the standard means of hemostasis were applied, and a treatment group, in which the standard means to control local bleeding were applied and a fibrin tissue adhesive was sprayed on the internal aspects of the operative field before skin closure. All operations were performed in a bloodless field with use of a pneumatic tourniquet. All patients received low-molecular-weight heparin as thromboprophylaxis twelve hours before the operation and every twelve hours postoperatively. Blood loss during the operation was evaluated by measuring the volume in the suction apparatus and by estimating the amount of lost blood in the swabs at the end of the operation. The apparent postoperative lost blood was determined by measuring the volume in the suction-drain bottles. All blood transfusions were recorded. RESULTS: The mean apparent postoperative blood loss (and standard deviation) in the fibrin-tissue-adhesive group was 360+/-287.7 milliliters compared with 878+/-403.0 milliliters in the control group, with a mean difference of 518 milliliters (p<0.001). The decrease in the level of hemoglobin was 25+/-10 grams per liter in the treatment group compared with 37+/-12 grams per liter in the control group (p<0.001). Sixteen patients (55 percent) in the control group required a blood transfusion and eight (28 percent) required two units of blood, whereas only five (17 percent) of the patients in the fibrin-tissue-adhesive group required a blood transfusion and only one (3 percent) required two units (p = 0.004). The number of adverse events was comparable between the two groups. None of the adverse events were considered to be related to the use of fibrin tissue adhesive. One death, which was due to massive pulmonary embolism, was reported in the control group. No seroconversion was reported at three and six months after the operation. CONCLUSION: The use of fibrin tissue adhesive in total knee arthroplasty seems to be an effective and safe means with which to reduce blood loss and blood-transfusion requirements. Furthermore, the importance of these findings was enhanced by a significant reduction in blood loss, in the postoperative decrease in the level of hemoglobin, and in blood-transfusion requirements despite preoperative thromboprophylaxis with low-molecular-weight heparin.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Wong, J., Abrishami, A., El Beheiry, H., Mahomed, N. N., Roderick Davey, J., Gandhi, R., Syed, K. A., Muhammad Ovais Hasan, S., De Silva, Y., & Chung, F. (2010) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/jbjs.i.01518 · Cited by 491
Fibrin sealants in surgical practice: An overview
Jackson, M. R. (2001) · The American Journal of Surgery · doi:10.1016/s0002-9610(01)00770-x · Cited by 397
Surgical adhesives: Systematic review of the main types and development forecast
Duarte, A. P., Coelho, J. F., Bordado, J. C., Cidade, M. T., & Gil, M. H. (2012) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2011.12.003 · Cited by 365
Spotnitz, W. D. (2014) · ISRN Surgery · doi:10.1155/2014/203943 · Cited by 355
Metadata
- Authors
- LEVY, O., MARTINOWITZ, U., ORAN, A., TAUBER, C., & HOROSZOWSKI, H.
- Venue
- The Journal of Bone & Joint Surgery
- Published
- 1999-11
- Volume
- 81
- Issue
- 11
- Pages
- 1580-8
- ISSN
- 0021-9355 (ISSN-L)
- OpenAlex
- W2157882600
- Cited by
- 235
- References
- 0
- FWCI
- 2.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Use of Fibrin Tissue Adhesive to Reduce Blood Loss and the Need for Blood Transfusion After Total Knee Arthroplasty. A Prospective, Randomized, Multicenter Study*. https://app.cochat.ai/papers/10.2106/00004623-199911000-00010
- The paper
- LEVY, O., MARTINOWITZ, U., ORAN, A., TAUBER, C., & HOROSZOWSKI, H. (1999). The Use of Fibrin Tissue Adhesive to Reduce Blood Loss and the Need for Blood Transfusion After Total Knee Arthroplasty. A Prospective, Randomized, Multicenter Study*. The Journal of Bone & Joint Surgery. https://doi.org/10.2106/00004623-199911000-00010
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.