ACCURACY OF ULTRASOUND IMAGING OF THE ROTATOR CUFF IN SHOULDERS THAT ARE PAINFUL POSTOPERATIVELY
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Evaluation of the rotator cuff in a shoulder that has been persistently painful postoperatively could be challenging. Magnetic resonance imaging has been the preferred imaging method, but accuracy rates have been lower for those shoulders than for shoulders that have not been operated on; also, magnetic resonance imaging is susceptible to suture anchor artifact. The purpose of this study was to evaluate the diagnostic accuracy of ultrasound for evaluating the rotator cuff in shoulders that are painful postoperatively. METHODS: The records of forty-four consecutive patients who had undergone both a high-resolution ultrasound examination and subsequent shoulder arthroscopy were retrospectively reviewed. Thirty-four patients underwent rotator cuff repair at the time of the arthroscopy, and ten had subacromial decompression or another procedure without cuff repair. The results of the ultrasound examination were compared with the intraoperative findings of the arthroscopic examination (the "gold standard"). RESULTS: Ultrasound led to a correct diagnosis for forty of the forty-four patients. Twenty-two recurrent rotator cuff tears and twenty-two intact rotator cuffs were found at surgery. Ultrasound correctly identified twenty of the twenty-two rotator cuff tears (true-positive results) and twenty of the twenty-two intact rotator cuffs (true-negative results). Two intact cuffs were identified as having a full-thickness tear (false-positive results), and two cuffs with a full-thickness rotator cuff tear were identified as being intact (false-negative results). The sensitivity and specificity of ultrasound for identifying rotator cuff integrity postoperatively were 91% and 86%, respectively. The accuracy was 89%. CONCLUSIONS: Ultrasound is a highly accurate imaging study for evaluating the integrity of the rotator cuff in shoulders that have undergone an operation. Its accuracy for operatively treated shoulders appears to be comparable with that previously reported for shoulders that had not been operated on.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tendons, ligaments, and capsule of the rotator cuff. Gross and microscopic anatomy.
Clark, J. M., & Harryman, D. T. (1992) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199274050-00010 · Cited by 739
Teefey, S. A., Hasan, S. A., Middleton, W. D., Patel, M., Wright, R. W., & Yamaguchi, K. (2000) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-200004000-00005 · Cited by 514 · cited 2×
“Recently, Teefey et al.(2) reported on 100 consecutive patients who had undergone shoulder ultrasound prior to arthroscopy.”
BackgroundSelf-citationTeefey, S. A., Hasan, S. A., Middleton, W. D., Patel, M., Wright, R. W., & Yamaguchi, K. (2000) · PubMed · Cited by 428
Self-citationNonoperative Treatment of Rotator Cuff Tears
Hawkins, R. H., & Dunlop, R. (1995) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199512000-00028 · Cited by 142
Functional morphology of the supraspinatus tendon
Fallon, J., Blevins, F. T., Vogel, K., & Trotter, J. (2002) · Journal of Orthopaedic Research® · doi:10.1016/s0736-0266(02)00023-2 · Cited by 100
MR IMAGING OF THE POSTOPERATIVE SHOULDER
Longobardi, R. S. F., Rafii, M., & Minkoff, J. (1997) · Magnetic Resonance Imaging Clinics of North America · doi:10.1016/s1064-9689(21)00221-x · Cited by 20
Cited by
de Jesus, J. O., Parker, L., Frangos, A. J., & Nazarian, L. N. (2009) · American Journal of Roentgenology · doi:10.2214/ajr.08.1241 · Cited by 608
Fehringer, E. V., Sun, J., VanOeveren, L. S., Keller, B. K., & Matsen, F. A. (2008) · Journal of Shoulder and Elbow Surgery · doi:10.1016/j.jse.2008.05.039 · Cited by 247
Cigarette Smoking Increases the Risk for Rotator Cuff Tears
Baumgarten, K. M., Gerlach, D., Galatz, L. M., Teefey, S. A., Middleton, W. D., Ditsios, K., & Yamaguchi, K. (2010) · Clinical Orthopaedics & Related Research · doi:10.1007/s11999-009-0781-2 · Cited by 242
“Ultrasonography was used in this study to diagnose a rotator cuff tear because it is reliable and accurate for imaging preoperative and postoperative rotator cuff tears [13, 17, 18].”
MethodSelf-citationFactors Affecting Rotator Cuff Healing
Mall, N. A., Tanaka, M. J., Choi, L. S., & Paletta, G. A. (2014) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.m.00583 · Cited by 228
“(2000 and 2009) 100% 85% Prickett et al.(17) (2003) 91% 86% Dinnes et al.”
Anderson, K., Boothby, M., Aschenbrener, D., & Van Holsbeeck, M. (2006) · The American Journal of Sports Medicine · doi:10.1177/0363546506290187 · Cited by 216
Metadata
- Authors
- PRICKETT, W. D., TEEFEY, S. A., GALATZ, L. M., CALFEE, R. P., MIDDLETON, W. D., & YAMAGUCHI, K.
- Venue
- The Journal of Bone and Joint Surgery-American Volume
- Published
- 2003-06
- Volume
- 85
- Issue
- 6
- Pages
- 1084-1089
- ISSN
- 0021-9355 (ISSN-L)
- OpenAlex
- W2228849844
- Cited by
- 229
- References
- 6
- FWCI
- 4.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.