The DOI matches its Crossref record.
DETECTION AND QUANTIFICATION OF ROTATOR CUFF TEARS: COMPARISON OF ULTRASONOGRAPHIC, MAGNETIC RESONANCE IMAGING, AND ARTHROSCOPIC FINDINGS IN SEVENTY-ONE CONSECUTIVE CASES
Abstract
Background: Although many investigators have evaluated the accuracy of ultrasonography and magnetic resonance imaging for the detection of full and partial-thickness rotator cuff tears, few have directly compared the two tests. The purpose of our study was to compare the accuracy of the two tests for detection and measurement of the size of rotator cuff tears, with arthroscopic findings used as the standard. Methods: One hundred and twenty-four consecutive patients with shoulder pain were prospectively studied with ultrasonography and magnetic resonance imaging. Seventy-one had subsequent arthroscopy, and they formed the study group. The arthroscopic diagnosis was a full-thickness tear in forty-six patients, a partial-thickness tear in nineteen, and no tear in six. The presence or absence of a full or partial-thickness tear and the tear size as demonstrated by each imaging test and at the time of arthroscopy were recorded. The findings of the imaging tests and arthroscopy were then compared for each parameter. Results: Ultrasonography correctly identified forty-five of the forty-six full-thickness tears and magnetic resonance imaging, all forty-six. Ultrasonography correctly identified thirteen of the nineteen partial-thickness rotator cuff tears and magnetic resonance imaging, twelve of the nineteen. The overall accuracy for both imaging tests was 87%. Ultrasonography correctly predicted the degree of retraction of 73% of the full-thickness tears and the length of 85% of the partial-thickness tears, and magnetic resonance imaging correctly predicted the retraction and length of 63% and 75%, respectively. Ultrasonography correctly predicted the width of 87% of the full-thickness tears and 54% of the partial-thickness tears, and magnetic resonance imaging correctly predicted the width of 80% and 75%, respectively. No significant differences between ultrasonography and magnetic resonance imaging were demonstrated (p > 0.05). Conclusions: Ultrasonography and magnetic resonance imaging had comparable accuracy for identifying and measuring the size of full-thickness and partial-thickness rotator cuff tears. When an investigator has comparable experience with both imaging tests, the decision regarding which test to perform for rotator cuff assessment does not need to be based on accuracy concerns. The choice can be based on other factors, such as the importance of ancillary clinical information (regarding lesions of the glenoid labrum, joint capsule, or surrounding muscle or bone), the presence of an implanted device, patient tolerance, and cost. Level of Evidence: Diagnostic study, Level I-1 (testing of previously developed diagnostic criteria in series of consecutive patients [with universally applied reference “gold” standard]). See Instructions to Authors for a complete description of levels of evidence.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
de Jesus, J. O., Parker, L., Frangos, A. J., & Nazarian, L. N. (2009) · American Journal of Roentgenology · doi:10.2214/ajr.08.1241 · Cited by 608
Maman, E., Harris, C., White, L., Tomlinson, G., Shashank, M., & Boynton, E. (2009) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/jbjs.g.01335 · Cited by 300
Partial-Thickness Rotator Cuff Tears
Matava, M. J., Purcell, D. B., & Rudzki, J. R. (2005) · The American Journal of Sports Medicine · doi:10.1177/0363546505280213 · Cited by 264
Ultrasound of the shoulder: asymptomatic findings in men
Girish, G., Lobo, L. G., Jacobson, J. A., Morag, Y., Miller, B., & Jamadar, D. A. (2011) · American Journal of Roentgenology · doi:10.2214/ajr.11.6971 · Cited by 170
Kwong, C. A., Woodmass, J. M., Gusnowski, E. M., Bois, A. J., Leblanc, J., More, K. D., & Lo, I. K. Y. (2021) · Arthroscopy · doi:10.1016/j.arthro.2020.10.037 · Cited by 126
Metadata
- Authors
- TEEFEY, S. A., RUBIN, D. A., MIDDLETON, W. D., HILDEBOLT, C. F., LEIBOLD, R. A., & YAMAGUCHI, K.
- Venue
- The Journal of Bone and Joint Surgery-American Volume
- Published
- 2004-04
- Volume
- 86
- Issue
- 4
- Pages
- 708-716
- ISSN
- 0021-9355 (ISSN-L)
- OpenAlex
- W4297832561
- Cited by
- 476
- References
- 0
- FWCI
- 19.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: DETECTION AND QUANTIFICATION OF ROTATOR CUFF TEARS: COMPARISON OF ULTRASONOGRAPHIC, MAGNETIC RESONANCE IMAGING, AND ARTHROSCOPIC FINDINGS IN SEVENTY-ONE CONSECUTIVE CASES. https://app.cochat.ai/papers/10.2106/00004623-200404000-00007
- The paper
- TEEFEY, S. A., RUBIN, D. A., MIDDLETON, W. D., HILDEBOLT, C. F., LEIBOLD, R. A., & YAMAGUCHI, K. (2004). DETECTION AND QUANTIFICATION OF ROTATOR CUFF TEARS: COMPARISON OF ULTRASONOGRAPHIC, MAGNETIC RESONANCE IMAGING, AND ARTHROSCOPIC FINDINGS IN SEVENTY-ONE CONSECUTIVE CASES. The Journal of Bone and Joint Surgery-American Volume. https://doi.org/10.2106/00004623-200404000-00007
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.