TWO-STAGE REVISION HIP ARTHROPLASTY FOR INFECTION: COMPARISON BETWEEN THE INTERIM USE OF ANTIBIOTIC-LOADED CEMENT BEADS AND A SPACER PROSTHESIS
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Background: A two-stage revision is a well-accepted method for the treatment of a deep infection of a hip with a joint implant. In the present study, the results associated with the interim use of antibiotic-loaded cement beads were compared with those associated with the interim use of an antibiotic-loaded cement prosthesis. Methods: One hundred and twenty-eight consecutive patients who were managed with a two-stage revision hip arthroplasty for the treatment of an infection were followed clinically and radiographically for an average of 4.9 years. Cement beads were implanted following resection arthroplasty in the first seventy hips, and a custom cement prosthesis was implanted in the subsequent fifty-eight hips. Results: There was no evidence of recurrent infection in 122 patients (95.3%); the infection-free rates in both groups were similar. The use of a spacer prosthesis was associated with a higher hip score, a shorter hospital stay, and better walking capacity in the interim period; a decreased operative time, less blood loss, and a lower transfusion requirement at the time of reimplantation; and fewer postoperative dislocations. Conclusions: The present study supports the safety and efficacy of the routine use of an antibiotic-loaded cement prosthesis in the interim between the stages of a two-stage revision procedure for the treatment of an infection at the site of a hip arthroplasty. Level of Evidence: Therapeutic study, Level III-2 (retrospective cohort study). See Instructions to Authors for a complete description of levels of evidence.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
HARRIS, W. H. (1969) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-196951040-00012 · Cited by 5,640
FUNCTIONAL RESULTS OF HIP ARTHROPLASTY WITH ACRYLIC PROSTHESIS
DʼAubigné, R. M., & Postel, M. (1954) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-195436030-00001 · Cited by 1,653
Infection after total hip arthroplasty. Past, present, and future.
Garvin, K. L., & Hanssen, A. D. (1995) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199510000-00015 · Cited by 497
Two-stage reconstruction of a total hip arthroplasty because of infection.
McDonald, D. J., Fitzgerald, R. H., & Ilstrup, D. M. (1989) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198971060-00005 · Cited by 276 · cited 2×
“McDonald et al.17, in a report on the results of eighty-two two-stage reconstructions that had been performed for the treatment of infection at the site of a hip arthroplasty, recommended at least four weeks of intravenous antibiotic therapy when antibiotic-impregnated material is not used.”
BackgroundThe Role of Antibiotic-Loaded Cement in the Treatment of an Infection after a Hip Replacement
Duncan, C. P., & Masri, B. A. (1994) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-199411000-00020 · Cited by 154
Younger, A. S. E., Duncan, C. P., & Masri, B. A. (1998) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-199801000-00011 · Cited by 128
Berry, D. J., Chandler, H. P., & Reilly, D. T. (1991) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-199173100-00003 · Cited by 125
Cited by
Campoccia, D., Montanaro, L., Speziale, P., & Arciola, C. R. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.05.005 · Cited by 392
Cui, Q., Mihalko, W. M., Shields, J. S., Ries, M., & Saleh, K. J. (2007) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200704000-00026 · Cited by 377
Elution of gentamicin and vancomycin from polymethylmethacrylate beads and hip spacers in vivo
Anagnostakos, K., Wilmes, P., Schmitt, E., & Kelm, J. (2009) · Acta Orthopaedica · doi:10.3109/17453670902884700 · Cited by 211
Biodegradable vs non-biodegradable antibiotic delivery devices in the treatment of osteomyelitis
Kluin, O. S., van der Mei, H. C., Busscher, H. J., & Neut, D. (2013) · Expert Opinion on Drug Delivery · doi:10.1517/17425247.2013.751371 · Cited by 171
“Although the therapeutic value of antibioticloaded PMMA in revision surgery has been suggested over the years [24,25], it has never been demonstrated convincingly in well-executed, prospective studies [26].”
BackgroundKunutsor, S. K., Whitehouse, M. R., Blom, A. W., Beswick, A. D., & INFORM Team (2015) · PLOS ONE · doi:10.1371/journal.pone.0139166 · Cited by 166
Metadata
- Authors
- HSIEH, P.-H., SHIH, C.-H., CHANG, Y.-H., LEE, M. S., SHIH, H.-N., & YANG, W.-E.
- Venue
- The Journal of Bone and Joint Surgery-American Volume
- Published
- 2004-09
- Volume
- 86
- Issue
- 9
- Pages
- 1989-1997
- ISSN
- 0021-9355 (ISSN-L)
- OpenAlex
- W4319293044
- Cited by
- 222
- References
- 7
- FWCI
- 6.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: TWO-STAGE REVISION HIP ARTHROPLASTY FOR INFECTION: COMPARISON BETWEEN THE INTERIM USE OF ANTIBIOTIC-LOADED CEMENT BEADS AND A SPACER PROSTHESIS. https://app.cochat.ai/papers/10.2106/00004623-200409000-00018
- The paper
- HSIEH, P.-H., SHIH, C.-H., CHANG, Y.-H., LEE, M. S., SHIH, H.-N., & YANG, W.-E. (2004). TWO-STAGE REVISION HIP ARTHROPLASTY FOR INFECTION: COMPARISON BETWEEN THE INTERIM USE OF ANTIBIOTIC-LOADED CEMENT BEADS AND A SPACER PROSTHESIS. The Journal of Bone and Joint Surgery-American Volume. https://doi.org/10.2106/00004623-200409000-00018
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.