The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
DIAGNOSTIC ACCURACY OF A NEW CLINICAL TEST (THE THESSALY TEST) FOR EARLY DETECTION OF MENISCAL TEARS
Abstract
BACKGROUND: Clinical tests used for the detection of meniscal tears in the knee do not present acceptable diagnostic sensitivity and specificity values. Diagnostic accuracy is improved by arthroscopic evaluation or magnetic resonance imaging studies. The objective of this study was to evaluate the diagnostic accuracy of a new dynamic clinical examination test for the detection of meniscal tears. METHODS: Two hundred and thirteen symptomatic patients with knee injuries who were examined clinically, had magnetic resonance imaging studies performed, and underwent arthroscopic surgery and 197 asymptomatic volunteers who were examined clinically and had magnetic resonance imaging studies done of their normal knees were included in this study. For clinical examination, the medial and lateral joint-line tenderness test, the McMurray test, the Apley compression and distraction test, the Thessaly test at 5 degrees of knee flexion, and the Thessaly test at 20 degrees of knee flexion were used. For all clinical tests, the sensitivity, specificity, false-positive, false-negative, and diagnostic accuracy rates were calculated and compared with the arthroscopic and magnetic resonance imaging data for the test subjects and the magnetic resonance imaging data for the control population. RESULTS: The Thessaly test at 20 degrees of knee flexion had a high diagnostic accuracy rate of 94% in the detection of tears of the medial meniscus and 96% in the detection of tears of the lateral meniscus, and it had a low rate of false-positive and false-negative recordings. Other traditional clinical examination tests, with the exception of joint-line tenderness, which presented a diagnostic accuracy rate of 89% in the detection of lateral meniscal tears, showed inferior rates. CONCLUSIONS: The Thessaly test at 20 degrees of knee flexion can be used effectively as a first-line clinical screening test for meniscal tears, reducing the need for and the cost of modern magnetic resonance imaging methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Practical Statistics for Medical Research
Altman, D. G. (1990) · doi:10.1201/9780429258589 · Cited by 10,668
Cited by
Makris, E. A., Hadidi, P., & Athanasiou, K. A. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.06.037 · Cited by 1,116
Telemedicine in the Era of COVID-19: The Virtual Orthopaedic Examination
Tanaka, M. J., Oh, L. S., Martin, S. D., & Berkson, E. M. (2020) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.20.00609 · Cited by 312
Metadata
- Authors
- KARACHALIOS, T., HANTES, M., ZIBIS, A. H., ZACHOS, V., KARANTANAS, A. H., & MALIZOS, K. N.
- Venue
- The Journal of Bone and Joint Surgery-American Volume
- Published
- 2005-05
- Volume
- 87
- Issue
- 5
- Pages
- 955-962
- ISSN
- 0021-9355 (ISSN-L)
- OpenAlex
- W2095829445
- Cited by
- 207
- References
- 1
- FWCI
- 4.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: DIAGNOSTIC ACCURACY OF A NEW CLINICAL TEST (THE THESSALY TEST) FOR EARLY DETECTION OF MENISCAL TEARS. https://app.cochat.ai/papers/10.2106/00004623-200505000-00004
- The paper
- KARACHALIOS, T., HANTES, M., ZIBIS, A. H., ZACHOS, V., KARANTANAS, A. H., & MALIZOS, K. N. (2005). DIAGNOSTIC ACCURACY OF A NEW CLINICAL TEST (THE THESSALY TEST) FOR EARLY DETECTION OF MENISCAL TEARS. The Journal of Bone and Joint Surgery-American Volume. https://doi.org/10.2106/00004623-200505000-00004
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.