Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 516

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

EFFECT OF FEMORAL HEAD DIAMETER AND OPERATIVE APPROACH ON RISK OF DISLOCATION AFTER PRIMARY TOTAL HIP ARTHROPLASTY

BERRY, DANIEL J., VON KNOCH, MARIUS, SCHLECK, CATHY D., HARMSEN, WILLIAM S.·2005·The Journal of Bone and Joint Surgery-American Volume

Abstract

BACKGROUND: It has been postulated that use of a larger femoral head could reduce the risk of dislocation after total hip arthroplasty, but only limited clinical data have been presented as proof of this hypothesis. METHODS: From 1969 to 1999, 21,047 primary total hip arthroplasties with varying femoral head sizes were performed at one institution. Patients routinely were followed at defined intervals and were specifically queried about dislocation. The operative approach was anterolateral in 9155 arthroplasties, posterolateral in 3646, and transtrochanteric in 8246. The femoral head diameter was 22 mm in 8691 of the procedures, 28 mm in 8797, and 32 mm in 3559. RESULTS: One or more dislocations occurred in 868 of the 21,047 hips. The cumulative risk of first-time dislocation was 2.2% at one year, 3.0% at five years, 3.8% at ten years, and 6.0% at twenty years. The cumulative ten-year rate of dislocation was 3.1% following anterolateral approaches, 3.4% following transtrochanteric approaches, and 6.9% following posterolateral approaches. The cumulative ten-year rate of dislocation was 3.8% for 22-mm-diameter femoral heads, 3.0% for 28-mm heads, and 2.4% for 32-mm heads in hips treated with an anterolateral approach; 3.5% for 22-mm heads, 3.5% for 28-mm heads, and 2.8% for 32-mm heads in hips treated with a transtrochanteric approach; and 12.1% for 22-mm heads, 6.9% for 28-mm heads, and 3.8% for 32-mm heads in hips treated with a posterolateral approach. Multivariate analysis showed the relative risk of dislocation to be 1.7 for 22-mm compared with 32-mm heads and 1.3 for 28-mm compared with 32-mm heads. CONCLUSIONS: In total hip arthroplasty, a larger femoral head diameter was associated with a lower long-term cumulative risk of dislocation. The femoral head diameter had an effect in association with all operative approaches, but the effect was greatest in association with the posterolateral approach.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2106/00004623-200511000-00012

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 516

Metadata

Authors
BERRY, D. J., VON KNOCH, M., SCHLECK, C. D., & HARMSEN, W. S.
Venue
The Journal of Bone and Joint Surgery-American Volume
Published
2005-11
Volume
87
Issue
11
Pages
2456-2463
ISSN
0021-9355 (ISSN-L)
OpenAlex
W2018264090
Cited by
516
References
3
FWCI
10.88
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: EFFECT OF FEMORAL HEAD DIAMETER AND OPERATIVE APPROACH ON RISK OF DISLOCATION AFTER PRIMARY TOTAL HIP ARTHROPLASTY. https://app.cochat.ai/papers/10.2106/00004623-200511000-00012
The paper
BERRY, D. J., VON KNOCH, M., SCHLECK, C. D., & HARMSEN, W. S. (2005). EFFECT OF FEMORAL HEAD DIAMETER AND OPERATIVE APPROACH ON RISK OF DISLOCATION AFTER PRIMARY TOTAL HIP ARTHROPLASTY. The Journal of Bone and Joint Surgery-American Volume. https://doi.org/10.2106/00004623-200511000-00012

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.