Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 197

The DOI matches its Crossref record.

SURVIVORSHIP AND RETRIEVAL ANALYSIS OF SIKOMET METAL-ON-METAL TOTAL HIP REPLACEMENTS AT A MEAN OF SEVEN YEARS

MILOŠEV, INGRID, TREBŠE, RIHARD, KOVAČ, SIMON, CÖR, ANDREJ, PIŠOT, VENČESLAV · 2006 · The Journal of Bone and Joint Surgery-American Volume

Abstract

BACKGROUND: Second-generation metal-on-metal total hip replacements were introduced in the early 1990s with the aim of eliminating polyethylene wear and the resulting complications of osteolysis and aseptic loosening. The goal of the present study was to evaluate the intermediate-term results in a series of patients who were managed with one of these implants. METHODS: Between 1994 and 2002, we performed 640 total hip replacements in 591 patients with use of a Bicon-Plus cementless threaded cup with a polyethylene liner housing a metal inlay made of Sikomet low-carbon cobalt-chromium-molybdenum alloy that articulates with a Sikomet metal femoral head. Clinical and radiographic evaluation was performed retrospectively at a mean of 7.1 years postoperatively. Histologic analysis was performed on specimens retrieved from seventeen hips that were revised, and wear measurements were made for six hips that were revised. RESULTS: Thirty-four hips (thirty-four patients) were revised because of infection (six hips), aseptic loosening (twenty-three hips), pain without loosening (two hips), or other reasons (three hips). The survival rate of the prosthesis as a whole at ten years, with revision for any reason as the end point, was 0.91 (95% confidence interval, 0.88 to 0.95). The survival rate of the cup was 0.94 (95% confidence interval, 0.90 to 0.97), and that of the stem was 0.96 (95% confidence interval, 0.94 to 0.98). Linear or expansile osteolysis, or both, was observed on the radiographs of sixteen (64%) of the twenty-five hips that were revised because of aseptic loosening and/or pain. Histological analysis of pericapsular tissue was performed for seventeen of the twenty-five hips that were revised because of aseptic loosening and/or pain. Thirteen of these seventeen hips demonstrated a hypersensitivity-like reaction with aseptic inflammatory changes accompanied by moderate to extensive diffuse and perivascular infiltration of lymphocytes. In the six retrieved specimens that were subjected to wear analysis, the main wear mode was abrasive wear. The mean cumulative linear wear for the bearing was 31.3 microm, and the mean annual wear rate was 6.3 microm/yr. The mean clearance was 87.6 microm. CONCLUSIONS: After a mean duration of follow-up of seven years, aseptic loosening was the major reason for failure of Sikomet metal-on-metal prostheses. The histological findings and the prevalence of osteolysis suggest the possibility of a hypersensitivity-like immunological response to wear particles.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2106/00004623-200606000-00002

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 197

Metadata

Authors
MILOŠEV, I., TREBŠE, R., KOVAČ, S., CÖR, A., & PIŠOT, V.
Venue
The Journal of Bone and Joint Surgery-American Volume
Published
2006-06
Volume
88
Issue
6
Pages
1173-1182
ISSN
0021-9355 (ISSN-L)
OpenAlex
W2015436292
Cited by
197
References
0
FWCI
18.08
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: SURVIVORSHIP AND RETRIEVAL ANALYSIS OF SIKOMET METAL-ON-METAL TOTAL HIP REPLACEMENTS AT A MEAN OF SEVEN YEARS. https://app.cochat.ai/papers/10.2106/00004623-200606000-00002
The paper
MILOŠEV, I., TREBŠE, R., KOVAČ, S., CÖR, A., & PIŠOT, V. (2006). SURVIVORSHIP AND RETRIEVAL ANALYSIS OF SIKOMET METAL-ON-METAL TOTAL HIP REPLACEMENTS AT A MEAN OF SEVEN YEARS. The Journal of Bone and Joint Surgery-American Volume. https://doi.org/10.2106/00004623-200606000-00002

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.