The DOI matches its Crossref record.
SURVIVORSHIP AND RETRIEVAL ANALYSIS OF SIKOMET METAL-ON-METAL TOTAL HIP REPLACEMENTS AT A MEAN OF SEVEN YEARS
Abstract
BACKGROUND: Second-generation metal-on-metal total hip replacements were introduced in the early 1990s with the aim of eliminating polyethylene wear and the resulting complications of osteolysis and aseptic loosening. The goal of the present study was to evaluate the intermediate-term results in a series of patients who were managed with one of these implants. METHODS: Between 1994 and 2002, we performed 640 total hip replacements in 591 patients with use of a Bicon-Plus cementless threaded cup with a polyethylene liner housing a metal inlay made of Sikomet low-carbon cobalt-chromium-molybdenum alloy that articulates with a Sikomet metal femoral head. Clinical and radiographic evaluation was performed retrospectively at a mean of 7.1 years postoperatively. Histologic analysis was performed on specimens retrieved from seventeen hips that were revised, and wear measurements were made for six hips that were revised. RESULTS: Thirty-four hips (thirty-four patients) were revised because of infection (six hips), aseptic loosening (twenty-three hips), pain without loosening (two hips), or other reasons (three hips). The survival rate of the prosthesis as a whole at ten years, with revision for any reason as the end point, was 0.91 (95% confidence interval, 0.88 to 0.95). The survival rate of the cup was 0.94 (95% confidence interval, 0.90 to 0.97), and that of the stem was 0.96 (95% confidence interval, 0.94 to 0.98). Linear or expansile osteolysis, or both, was observed on the radiographs of sixteen (64%) of the twenty-five hips that were revised because of aseptic loosening and/or pain. Histological analysis of pericapsular tissue was performed for seventeen of the twenty-five hips that were revised because of aseptic loosening and/or pain. Thirteen of these seventeen hips demonstrated a hypersensitivity-like reaction with aseptic inflammatory changes accompanied by moderate to extensive diffuse and perivascular infiltration of lymphocytes. In the six retrieved specimens that were subjected to wear analysis, the main wear mode was abrasive wear. The mean cumulative linear wear for the bearing was 31.3 microm, and the mean annual wear rate was 6.3 microm/yr. The mean clearance was 87.6 microm. CONCLUSIONS: After a mean duration of follow-up of seven years, aseptic loosening was the major reason for failure of Sikomet metal-on-metal prostheses. The histological findings and the prevalence of osteolysis suggest the possibility of a hypersensitivity-like immunological response to wear particles.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Nanomaterials and nanoparticles: Sources and toxicity
Buzea, C., Pacheco, I. I., & Robbie, K. (2007) · Biointerphases · doi:10.1116/1.2815690 · Cited by 3,789
Keegan, G. M., Learmonth, I. D., & Case, C. P. (2007) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.89b5.18903 · Cited by 321
The effects on bone cells of metal ions released from orthopaedic implants. A review
Sansone, V (2013) · CLINICAL CASES IN MINERAL AND BONE METABOLISM · doi:10.11138/ccmbm/2013.10.1.034 · Cited by 289
Caicedo, M. S., Desai, R., McAllister, K., Reddy, A., Jacobs, J. J., & Hallab, N. J. (2009) · Journal of Orthopaedic Research · doi:10.1002/jor.20826 · Cited by 257
Metadata
- Authors
- MILOŠEV, I., TREBŠE, R., KOVAČ, S., CÖR, A., & PIŠOT, V.
- Venue
- The Journal of Bone and Joint Surgery-American Volume
- Published
- 2006-06
- Volume
- 88
- Issue
- 6
- Pages
- 1173-1182
- ISSN
- 0021-9355 (ISSN-L)
- OpenAlex
- W2015436292
- Cited by
- 197
- References
- 0
- FWCI
- 18.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: SURVIVORSHIP AND RETRIEVAL ANALYSIS OF SIKOMET METAL-ON-METAL TOTAL HIP REPLACEMENTS AT A MEAN OF SEVEN YEARS. https://app.cochat.ai/papers/10.2106/00004623-200606000-00002
- The paper
- MILOŠEV, I., TREBŠE, R., KOVAČ, S., CÖR, A., & PIŠOT, V. (2006). SURVIVORSHIP AND RETRIEVAL ANALYSIS OF SIKOMET METAL-ON-METAL TOTAL HIP REPLACEMENTS AT A MEAN OF SEVEN YEARS. The Journal of Bone and Joint Surgery-American Volume. https://doi.org/10.2106/00004623-200606000-00002
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.