The DOI matches its Crossref record.
The Cost-Effectiveness of Computer-Assisted Navigation in Total Knee Arthroplasty
Open accessAbstract
BACKGROUND: Total knee arthroplasty is one of the most clinically successful and cost-effective interventions in medicine. However, implant malalignment, especially in the coronal plane, is a common cause of early failure following total knee arthroplasty. Computer-assisted surgery has been employed during total knee arthroplasty to improve the precision of component alignment. The purpose of the present study was to evaluate the cost-effectiveness of computer-assisted surgery to determine whether the improved alignment achieved with computer navigation provides a sufficient decrease in failure rates and revisions to justify the added cost. METHODS: A decision-analysis model was used to estimate the cost-effectiveness of computer-assisted surgery in total knee arthroplasty. Model inputs, including costs, effectiveness, and clinical outcome probabilities, were obtained from a review of the literature. Sensitivity analyses were performed to evaluate the impact of component-alignment precision with use of computer-assisted and mechanical alignment guides, total knee arthroplasty failure rates secondary to malalignment, and costs of computer-assisted surgery systems on the cost-effectiveness of computer navigation in total knee arthroplasty. RESULTS: Computer-assisted surgery is both more effective and more expensive than mechanical alignment systems. Given an additional cost of $1500 per operation, a 14% improvement in coronal alignment precision (within 3 degrees of neutral mechanical axis), and an elevenfold increase in revision rates at fifteen years with coronal malalignment (54% compared with 4.7%), the incremental cost of using computer-assisted surgery is $45,554 per quality-adjusted life-year gained. Cost-savings is achieved if the added cost of computer-assisted surgery is $629 or less per operation. Variability in published clinical outcomes, however, introduces uncertainty in determining the cost-effectiveness. CONCLUSIONS: Computer-assisted surgery is potentially a cost-effective or cost-saving addition to total knee arthroplasty. However, the cost-effectiveness is sensitive to variability in the costs of computer navigation systems, the accuracy of alignment achieved with computer navigation, and the probability of revision total knee arthroplasty with malalignment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Why Are Total Knees Failing Today? Etiology of Total Knee Revision in 2010 and 2011
Schroer, W. C., Berend, K. R., Lombardi, A. V., Barnes, C. L., Bolognesi, M. P., Berend, M. E., Ritter, M. A., & Nunley, R. M. (2013) · The Journal of Arthroplasty · doi:10.1016/j.arth.2013.04.056 · Cited by 423
The cost-effectiveness of total joint arthroplasty: A systematic review of published literature
Daigle, M. E., Weinstein, A. M., Katz, J. N., & Losina, E. (2012) · Best Practice & Research Clinical Rheumatology · doi:10.1016/j.berh.2012.07.013 · Cited by 333
Bonner, T. J., Eardley, W. G. P., Patterson, P., & Gregg, P. J. (2011) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.93b9.26573 · Cited by 302
Computer Assisted Knee Replacement Surgery: Is the Movement Mainstream?
Picard, F. (2014) · Orthopedic & Muscular System · doi:10.4172/2161-0533.1000153 · Cited by 23
Metadata
- Authors
- Novak, E. J., Silverstein, M. D., & Bozic, K. J.
- Venue
- The Journal of Bone and Joint Surgery-American Volume
- Published
- 2007-11
- Volume
- 89
- Issue
- 11
- Pages
- 2389-2397
- ISSN
- 0021-9355 (ISSN-L)
- OpenAlex
- W2098727995
- Cited by
- 181
- References
- 0
- FWCI
- 8.26
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Cost-Effectiveness of Computer-Assisted Navigation in Total Knee Arthroplasty. https://app.cochat.ai/papers/10.2106/00004623-200711000-00008
- The paper
- Novak, E. J., Silverstein, M. D., & Bozic, K. J. (2007). The Cost-Effectiveness of Computer-Assisted Navigation in Total Knee Arthroplasty. The Journal of Bone and Joint Surgery-American Volume. https://doi.org/10.2106/00004623-200711000-00008
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).