Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 578

The DOI matches its Crossref record.

Reverse Shoulder Arthroplasty for the Treatment of Rotator Cuff Deficiency

Cuff, Derek, Pupello, Derek, Virani, Nazeem, Levy, Jonathan, Frankle, Mark·2008·The Journal of Bone & Joint Surgery

Abstract

BACKGROUND: Early designs of reverse shoulder arthroplasty components for the treatment of glenohumeral arthritis associated with severe rotator cuff deficiency in some cases have been associated with mechanical failure. The purpose of this study was to perform a prospective outcomes study of reverse shoulder arthroplasty performed with use of 5.0-mm peripheral locking screws for baseplate fixation and a lateralized center of rotation for the treatment of a rotator cuff deficiency. METHODS: From February 2004 to March 2005, 112 patients (114 shoulders) were treated with a reverse shoulder arthroplasty as part of a United States Food and Drug Administration Investigational Device Exemption study. Ninety-four patients (ninety-six shoulders) were available for a minimum follow-up of two years. Of the ninety-six shoulders, thirty-seven had a primary rotator cuff deficiency, thirty-three had a previous rotator cuff operation, twenty-three had a previous arthroplasty, and three had a proximal humeral nonunion. The patients were prospectively followed clinically (the American Shoulder and Elbow Surgeons [ASES] score, the Simple Shoulder Test [SST], and self-reported satisfaction) and radiographically (mechanical failure, loosening, and notching). Patients were videotaped while performing a standard active range-of-motion protocol before and after treatment. These videos were then analyzed in a blinded fashion by three independent observers using a digital goniometer. RESULTS: At two years, the average total ASES scores had improved from 30 preoperatively to 77.6; the average ASES pain scores, from 15 to 41.6; and the average SST scores, from 1.8 to 6.8 (p < 0.0001 for all). Blinded analysis of range of motion showed that average abduction improved from 61 degrees preoperatively to 109.5 degrees (p < 0.0001); average flexion, from 63.5 degrees to 118 degrees (p < 0.0001); and average external rotation, from 13.4 degrees to 28.2 degrees (p < 0.0001). The patients rated the outcome as excellent in fifty-three shoulders (55%), good in twenty-six (27%), satisfactory in eleven (12%), and unsatisfactory in six (6%). There was no evidence of mechanical failure of the baseplate or scapular notching in any of the patients. Six of the ninety-four patients in this study had a complication. CONCLUSIONS: Recent advances in reverse shoulder arthroplasty have allowed for improvement in patient outcomes while minimizing early mechanical failure and scapular notching and decreasing the overall complication rate at short-term follow-up.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2106/jbjs.g.00775

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 578

Metadata

Authors
Cuff, D., Pupello, D., Virani, N., Levy, J., & Frankle, M.
Venue
The Journal of Bone & Joint Surgery
Published
2008-06
Volume
90
Issue
6
Pages
1244-1251
ISSN
0021-9355 (ISSN-L)
OpenAlex
W2127461613
Cited by
578
References
0
FWCI
24.89
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Reverse Shoulder Arthroplasty for the Treatment of Rotator Cuff Deficiency. https://app.cochat.ai/papers/10.2106/jbjs.g.00775
The paper
Cuff, D., Pupello, D., Virani, N., Levy, J., & Frankle, M. (2008). Reverse Shoulder Arthroplasty for the Treatment of Rotator Cuff Deficiency. The Journal of Bone & Joint Surgery. https://doi.org/10.2106/jbjs.g.00775

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.