Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 178

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Radiographic Identification of the Primary Medial Knee Structures

Wijdicks, Coen A, Griffith, Chad J, LaPrade, Robert F, Johansen, Steinar, Sunderland, Adam, Arendt, Elizabeth A, Engebretsen, Lars·2009·The Journal of Bone and Joint Surgery-American Volume

Abstract

BACKGROUND: Radiographic landmarks for medial knee attachment sites during anatomic repairs or reconstructions are unknown. If identified, they could assist in the preoperative evaluation of structure location and allow for postoperative assessment of reconstruction tunnel placement. METHODS: Radiopaque markers were implanted into the femoral and tibial attachments of the superficial medial collateral ligament and the femoral attachments of the posterior oblique and medial patellofemoral ligaments of eleven fresh-frozen, nonpaired cadaveric knee specimens. Both anteroposterior and lateral radiographs were made. Structures were assessed within quadrants formed by the intersection of reference lines projected on the lateral radiographs. Quantitative measurements were performed by three independent examiners. Intraobserver reproducibility and interobserver reliability were determined with use of intraclass correlation coefficients. RESULTS: The overall intraclass correlation coefficients for intraobserver reproducibility and interobserver reliability were 0.996 and 0.994, respectively. On the anteroposterior radiographs, the attachment sites of the superficial medial collateral ligament, posterior oblique ligament, and medial patellofemoral ligament were 30.5 +/- 2.4 mm, 34.8 +/- 2.7 mm, and 42.3 +/- 2.1 mm from the femoral joint line, respectively. On the lateral femoral radiographs, the attachment of the superficial medial collateral ligament was 6.0 +/- 0.8 mm from the medial epicondyle and was located in the anterodistal quadrant. The attachment of the posterior oblique ligament was 7.7 +/- 1.9 mm from the gastrocnemius tubercle and was located in the posterodistal quadrant. The attachment of the medial patellofemoral ligament was 8.9 +/- 2.0 mm from the adductor tubercle and was located in the anteroproximal quadrant. On the lateral tibial radiographs, the proximal and distal tibial attachments of the superficial medial collateral ligament were 15.9 +/- 5.2 and 66.1 +/- 3.6 mm distal to the tibial inclination, respectively. CONCLUSIONS: The attachment locations of the main medial knee structures can be qualitatively and quantitatively correlated to osseous landmarks and projected radiographic lines, with close agreement among examiners.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2106/jbjs.h.00909

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 178

Metadata

Authors
Wijdicks, C. A., Griffith, C. J., LaPrade, R. F., Johansen, S., Sunderland, A., Arendt, E. A., & Engebretsen, L.
Venue
The Journal of Bone and Joint Surgery-American Volume
Published
2009-03
Volume
91
Issue
3
Pages
521-529
ISSN
0021-9355 (ISSN-L)
OpenAlex
W2107833818
Cited by
178
References
2
FWCI
8.00
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.