CoChat

Surgical Coaching from Head-Mounted Video in the Training of Fluoroscopically Guided Articular Fracture Surgery

Karam, Matthew D., Thomas, Geb W., Koehler, Daniel M., Westerlind, Brian O., Lafferty, Paul M., Ohrt, Gary Thomas, Marsh, J. Lawrence, Van Heest, Ann E., Anderson, Donald D. · 2015 · Journal of Bone and Joint Surgery
Cited by 81

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

BACKGROUND: The evolving surgical skills education paradigm in orthopaedics has generated a strong demand for validated educational tools and methodologies. This study aimed to confirm that a one-on-one faculty coaching review of the head-mounted video recording of a resident's surgical performance on a validated articular fracture simulation trainer would substantially improve subsequent performance. METHODS: Fifteen first-year or second-year orthopaedic surgery residents reduced and fixed a standardized intra-articular tibial plafond fracture model under fluoroscopic guidance. Their performances were recorded by a head-mounted video camera. Prior to repeating the procedure six weeks later, eight subjects (the intervention group) reviewed the video of their performance with an orthopaedic traumatologist, and seven subjects (the control group) did not. Cohort performance was compared with respect to task duration, number of fluoroscopic images, and scores on the Objective Structured Assessment of Technical Skills (OSATS) as evaluated by fellowship-trained orthopaedic traumatologists blinded to the residents' year in training and prior surgical experience. RESULTS: The initial performance OSATS scores were not significantly different (p ≥ 0.05) between the control and intervention groups. Assessments of their repeat performance showed a significant net interval improvement (p < 0.05) in OSATS scores in the intervention group (mean [and standard deviation], 21 ± 8 points) compared with the control group (6 ± 3 points). The mean fluoroscopy utilization had a significant net decrease (p < 0.05) in the intervention group (-5.4 ± 11.7 points) compared with the control group (5.3 ± 7.0 points). Task duration in the repeat performance was similar between both groups. CONCLUSIONS: Personalized video-based feedback improved performance on a standardized articular fracture trainer for first-year and second-year residents. The described technique may further enhance resident surgical skills education.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2106/jbjs.n.00748

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Research works printed but not linked: 7

  1. Karam, 2013, Current and future use of surgical skills training laboratories in orthopaedic resident education: a national survey, J Bone Joint Surg Am., 95, e4, 10.2106/JBJS.L.00177 · DOI · Paper page
  2. Yehyawi, 2013, A simulation trainer for complex articular fracture surgery, J Bone Joint Surg Am., 95, e92, 10.2106/JBJS.L.00554 · doi:10.2106/jbjs.l.00554
  3. Seymour, 2002, Virtual reality training improves operating room performance: results of a randomized, double-blinded study, Ann Surg., 236, 458, 10.1097/00000658-200210000-00008 · DOI · Paper page
  4. Butler, 2013, Do the skills acquired by novice surgeons using anatomic dry models transfer effectively to the task of diagnostic knee arthroscopy performed on cadaveric specimens?, J Bone Joint Surg Am., 95, 10.2106/JBJS.L.00491 · DOI
  5. Mabrey, 2010, Virtual reality in orthopaedics: is it a reality?, Clin Orthop Relat Res., 468, 2586, 10.1007/s11999-010-1426-1 · doi:10.1007/s11999-010-1426-1
  6. Karam, 2012, Application of surgical skill simulation training and assessment in orthopaedic trauma, Iowa Orthop J., 32, 76
  7. Reznick, 1997, Testing technical skill via an innovative “bench station” examination, Amer J Surg., 173, 226, 10.1016/S0002-9610(97)89597-9 · DOI · Paper page

Cited by

Metadata

Authors
Karam, M. D., Thomas, G. W., Koehler, D. M., Westerlind, B. O., Lafferty, P. M., Ohrt, G. T., Marsh, J. L., Van Heest, A. E., & Anderson, D. D.
Venue
Journal of Bone and Joint Surgery
Published
2015-06-17
Volume
97
Issue
12
Pages
1031-1039
ISSN
  • 0021-9355 (ISSN-L)
  • 1535-1386
OpenAlex
W1904632131
Cited by
81
References
1
FWCI
6.67
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.